Thermal study of an aluminium nitride ceramic heater for spray CVD on glass substrates by quantitative thermography
RIOU, Olivier
Centre d'Etudes et Recherches en Thermique, Environnement et Systèmes [Créteil] [CERTES EA 3481]
Centre d'Etudes et Recherches en Thermique, Environnement et Systèmes [Créteil] [CERTES EA 3481]
LOGERAIS, Pierre-Olivier
Centre d'Etudes et Recherches en Thermique, Environnement et Systèmes [Créteil] [CERTES EA 3481]
Voir plus >
Centre d'Etudes et Recherches en Thermique, Environnement et Systèmes [Créteil] [CERTES EA 3481]
RIOU, Olivier
Centre d'Etudes et Recherches en Thermique, Environnement et Systèmes [Créteil] [CERTES EA 3481]
Centre d'Etudes et Recherches en Thermique, Environnement et Systèmes [Créteil] [CERTES EA 3481]
LOGERAIS, Pierre-Olivier
Centre d'Etudes et Recherches en Thermique, Environnement et Systèmes [Créteil] [CERTES EA 3481]
Centre d'Etudes et Recherches en Thermique, Environnement et Systèmes [Créteil] [CERTES EA 3481]
DURASTANTI, Jean-Félix
Centre d'Etudes et Recherches en Thermique, Environnement et Systèmes [Créteil] [CERTES EA 3481]
< Réduire
Centre d'Etudes et Recherches en Thermique, Environnement et Systèmes [Créteil] [CERTES EA 3481]
Langue
en
Article de revue
Ce document a été publié dans
Quantitative InfraRed Thermography Journal. 2013-05, vol. 10, n° 2, p. 159-171
Taylor and Francis
Résumé en anglais
A thermographic approach is used to determine the temperature of an aluminium nitride hot plate as a glass substrate heater for depositing thin films by spray CVD (Chemical Vapour Deposition). In this context, the temperature ...Lire la suite >
A thermographic approach is used to determine the temperature of an aluminium nitride hot plate as a glass substrate heater for depositing thin films by spray CVD (Chemical Vapour Deposition). In this context, the temperature of the hot plate is conditioned by the evaluation of both effective emissivity and environment temperature with calibration curve of the commercial camera. We first examined the consistency of the thermosignal/temperature correspondence by employing the software calibration. The environment temperature is evaluated by means of a ruffled aluminium foil according to ASTM. The effective emissivity is measured in situ by using a commercial IR camera on the temperature range of [40°C, 540°C] with a better than 3% accuracy. Absolute value of effective emissivity is in agreement with spectrometric values up to 120°C. Above this temperature, a strong dependence with temperature is highlighted. The radiometric temperature values are thereby corrected with an exactitude of temperature better than 2.5% in Celsius degree for the highest temperatures considered.< Réduire
Mots clés en anglais
hot plate heating
effective emissivity
spectral emissivity
radiometric temperature correction
measurement uncertainty
Origine
Importé de halUnités de recherche