Gross Error Detection Applied to a Wind Turbine
Idioma
EN
Communication dans un congrès
Este ítem está publicado en
CESA 06, IEEE multiconference on Computational Engineering in Systems Applications, CESA 06, IEEE multiconference on Computational Engineering in Systems Applications, 2006-10-04, Beijing. 2006p. 843 - 850 , ISBN: 7-900718-14-1
Resumen en inglés
This paper present a method to identify and estimate gross errors for linear dynamic systems. This method is applied to the doubly fed induction generator (DFIG) of a wind turbine. Gross error detection is used not only ...Leer más >
This paper present a method to identify and estimate gross errors for linear dynamic systems. This method is applied to the doubly fed induction generator (DFIG) of a wind turbine. Gross error detection is used not only to improve the estimation accuracy of data reconciliation procedures but also to identify instrumentation problems by using statistical tests.< Leer menos
Palabras clave en inglés
Diagnosis
dynamic systems
error detection
polynomial methods
Centros de investigación