Numerical Workflow of Irreversible Electroporation for Deep-Seated Tumor
Idioma
en
Article de revue
Este ítem está publicado en
Physics in Medicine and Biology. 2019-03-01, vol. 64, n° 5, p. 055016
IOP Publishing
Resumen en inglés
The paper provides a numerical workflow, based on the “real-life” clinical workflow of irreversible electroporation (IRE) performed for the treatment of deep-seated liver tumors. Thanks to a combination of numerical ...Leer más >
The paper provides a numerical workflow, based on the “real-life” clinical workflow of irreversible electroporation (IRE) performed for the treatment of deep-seated liver tumors. Thanks to a combination of numerical modeling, image registration algorithm and clinical data, our numerical workflow enables to provide the distribution of the electric field as effectively delivered by the clinical IRE procedure. As a proof of concept, we show on a specific clinical case of IRE ablation of liver tumor that clinical data could be advantageously combined to numerical simulations in a near future, in order to give to the interventional radiologists information on the effective IRE ablation. We also corroborate the simulated treated region with the post-treatment MRI performed 3 days after the treatment< Leer menos
Proyecto ANR
Initiative d'excellence de l'Université de Bordeaux - ANR-10-IDEX-0003
Orígen
Importado de HalCentros de investigación