Xylem resistance to embolism: presenting a simple diagnostic test for the open vessel artefact
COCHARD, Hervé
Laboratoire de Physique et Physiologie Intégratives de l’Arbre en environnement Fluctuant [PIAF]
Leer más >
Laboratoire de Physique et Physiologie Intégratives de l’Arbre en environnement Fluctuant [PIAF]
COCHARD, Hervé
Laboratoire de Physique et Physiologie Intégratives de l’Arbre en environnement Fluctuant [PIAF]
Laboratoire de Physique et Physiologie Intégratives de l’Arbre en environnement Fluctuant [PIAF]
LOPEZ RODRIGUEZ, Rosa Ana
Hawkesbury Institute for the Environment [Richmond] [HIE]
Laboratoire de Physique et Physiologie Intégratives de l’Arbre en environnement Fluctuant [PIAF]
Hawkesbury Institute for the Environment [Richmond] [HIE]
Laboratoire de Physique et Physiologie Intégratives de l’Arbre en environnement Fluctuant [PIAF]
BADEL, Eric
Laboratoire de Physique et Physiologie Intégratives de l’Arbre en environnement Fluctuant [PIAF]
< Leer menos
Laboratoire de Physique et Physiologie Intégratives de l’Arbre en environnement Fluctuant [PIAF]
Idioma
en
Article de revue
Este ítem está publicado en
New Phytologist. 2017, vol. 215, n° 1, p. np
Wiley
Resumen en inglés
Xylem vulnerability to embolism represents an essential trait for the evaluation of the impact of hydraulics in plant function and ecology. The standard centrifuge technique is widely used for the construction of vulnerability ...Leer más >
Xylem vulnerability to embolism represents an essential trait for the evaluation of the impact of hydraulics in plant function and ecology. The standard centrifuge technique is widely used for the construction of vulnerability curves, although its accuracy when applied to species with long vessels remains under debate. We developed a simple diagnostic test to determine whether the open-vessel artefact influences centrifuge estimates of embolism resistance. Xylem samples from three species with differing vessel lengths were exposed to less negative xylem pressures via centrifugation than the minimum pressure the sample had previously experienced. Additional calibration was obtained from non-invasive measurement of embolism on intact olive plants by X-ray microtomography. Results showed artefactual decreases in hydraulic conductance (k) for samples with open vessels when exposed to a less negative xylem pressure than the minimum pressure they had previously experienced. X-Ray microtomography indicated that most of the embolism formation in olive occurs at xylem pressures below -4.0 MPa, reaching 50% loss of hydraulic conductivity at -5.3 MPa. The artefactual reductions in k induced by centrifugation underestimate embolism resistance data of species with long vessels. A simple test is suggested to avoid this open vessel artefact and to ensure the reliability of this technique in future studies.< Leer menos
Palabras clave
xylème
artefact
activité hydraulique
biologie de la plante
centrifugation
microtomographie
courbe de vulnérabilité
embolie des vaisseaux
Palabras clave en inglés
centrifuge technique
embolism
micro-CT
olive
xylem
artifact
centrifuging
Proyecto europeo
Plasticity and adaptation of hydraulic traits to overcome climate change
Proyecto ANR
Plateforme d'Innovation " Forêt-Bois-Fibre-Biomasse du Futur "
Orígen
Importado de HalCentros de investigación