Hybrid piezochromic coatings for impact detection on composite substrates for aeronautic
MORELLE, Quentin
Laboratoire de Chimie de la Matière Condensée de Paris [LCMCP]
Matériaux Hybrides et Procédés [LCMCP-MHP ]
Laboratoire de Chimie de la Matière Condensée de Paris [LCMCP]
Matériaux Hybrides et Procédés [LCMCP-MHP ]
NICOLE, Lionel
Laboratoire de Chimie de la Matière Condensée de Paris [LCMCP]
Matériaux Hybrides et Procédés [LCMCP-MHP ]
Voir plus >
Laboratoire de Chimie de la Matière Condensée de Paris [LCMCP]
Matériaux Hybrides et Procédés [LCMCP-MHP ]
MORELLE, Quentin
Laboratoire de Chimie de la Matière Condensée de Paris [LCMCP]
Matériaux Hybrides et Procédés [LCMCP-MHP ]
Laboratoire de Chimie de la Matière Condensée de Paris [LCMCP]
Matériaux Hybrides et Procédés [LCMCP-MHP ]
NICOLE, Lionel
Laboratoire de Chimie de la Matière Condensée de Paris [LCMCP]
Matériaux Hybrides et Procédés [LCMCP-MHP ]
Laboratoire de Chimie de la Matière Condensée de Paris [LCMCP]
Matériaux Hybrides et Procédés [LCMCP-MHP ]
ROZES, Laurence
Laboratoire de Chimie de la Matière Condensée de Paris [LCMCP]
Matériaux Hybrides et Procédés [LCMCP-MHP ]
< Réduire
Laboratoire de Chimie de la Matière Condensée de Paris [LCMCP]
Matériaux Hybrides et Procédés [LCMCP-MHP ]
Langue
en
Article de revue
Ce document a été publié dans
Materials Letters. 2019-10, vol. 253, p. 140-143
Elsevier
Résumé en anglais
Structural Health Monitoring (SHM) is a major issue in the aeronautic field, especially for impact detection on composite materials which can be time consuming. Impact-sensitive coatings are an interesting way to save costs ...Lire la suite >
Structural Health Monitoring (SHM) is a major issue in the aeronautic field, especially for impact detection on composite materials which can be time consuming. Impact-sensitive coatings are an interesting way to save costs and time associated with these monitoring operations. This paper describes the successful preparation of a reversible piezochromic coating for impacts detection on composite substrates. It results from the incorporation of piezochromic pigments into a hybrid organic-inorganic matrix. It has been optimized by studying and quantifying their piezochromic behavior by UV-visible spectroscopy. It revealed that the piezochromic properties of the sensitive coating and the pigments alone are quite different and ruled by the hardness of the film. The obtained sensitivity and threshold pressure are determined to be 28% GPa−1 and 0.2 GPa respectively.< Réduire
Mots clés en anglais
Nanocomposites
Functional coating
Piezochromic
Project ANR
Revêtements Piézochromes Réversibles pour la Détection d'Impacts sur Supports Composites - ANR-13-RMNP-0011
Origine
Importé de halUnités de recherche