SuperNEMO experiment is unique 0νββ experiment taking advantage of topological reconstruction of events. In order to obtain trustworthy data cuts for future data analysis the study of different detector precision limits ...Leer más >
SuperNEMO experiment is unique 0νββ experiment taking advantage of topological reconstruction of events. In order to obtain trustworthy data cuts for future data analysis the study of different detector precision limits is needed. In this paper, we present simple method for vertex precision evaluation. We compare precision for different magnetic fields used in the particle tracker and performance for different energies of individual electrons.< Leer menos