dc.description.abstractDans un contexte de raréfaction des énergies à bas coût et de lutte contre le changement climatique, le secteur du bâtiment est contraint à des objectifs de diminution de ses consommations d'énergie. Un contrôle adapté des systèmes énergétiques du bâtiment peut constituer un levier important pour tendre vers cet objectif. Le but premier de ces travaux est la construction de modèles de faibles dimensions afin de pouvoir les embarquer dans un contrôleur pour améliorer la gestion énergétique. Ces modèles doivent être capables de s’enrichir des mesures disponibles sur site. Un bâtiment démonstrateur situé à l'Institut Universitaire de Technologie Génie Civil Construction Durable de Bordeaux sert de support au projet. Ce travail se décline en quatre volets. Le premier concerne la modélisation puisque des modèles légers basés sur l'analogie électrique et la représentation d'état sont proposés afin de décrire la dynamique du bâtiment sur un horizon de contrôle de quelques jours. Le deuxième volet concerne l'instrumentation du bâtiment puisque des campagnes de mesures courtes sont réalisées afin d'identifier les valeurs des paramètres du modèle de façon à minimiser l'écart modèle-mesure. Certains capteurs servent par la suite pour la gestion énergétique du bâtiment ; ces travaux posent donc également la question du jeu minimal de capteurs. Le troisième volet concerne la caractérisation des systèmes servant à piloter l'ambiance puisque dans une logique de contrôle optimal il faut être capable de relier l'effet de la commande sur la grandeur d'intérêt (température de confort). Le bâtiment démonstrateur comprend deux systèmes de chauffage : un plancher chauffant et des ventilo-convecteurs ainsi qu'une centrale de traitement d'air double flux pour le renouvellement d'air. Le dernier volet concerne la gestion énergétique avec l'utilisation d'un contrôleur prédictif embarquant l'un des modèles identifiés. Ainsi l’objectif est de chercher à anticiper le pilotage d'un système capacitif à long temps de réponse, tel que le plancher chauffant, grâce à la connaissance des perturbations futures (occupation, météo) sur un horizon de prédiction de quelques heures. Un contrôle réactif est assuré par les ventilo-convecteurs en appoint. La gestion prédictive est comparée à des stratégies de gestion plus classiques en simulation et in situ avec le bâtiment démonstrateur. L'originalité de ces travaux est de proposer une démarche pour la mise en place d'une boucle de contrôle complète (contrôleur/capteur /actionneurs) et de montrer s'il existe un intérêt à la gestion prédictive de systèmes à long temps de réponse dans le domaine du bâtiment.
dc.description.abstractEnThe building sector is forced to reduce its energy consumption in a context of high energy prices and global warming. Proper control of building energy systems can be an important lever to move towards this goal. The main goal of this work is to obtain small size buildings models in order to use it in a controller to improve energy management. The inputs of these models are fed in real-time with available measurements on site. A demonstration building at the IUT Civil Engineering and Sustainable Construction of Bordeaux serves as experimental support for the project. This work consists of four parts. The first one is to make lightweight models based on the electrical analogy and state-space representation to describe the dynamics of the building on upcoming days. The second part concerns the instrumentation of the building because short measurement campaigns are carried out to identify the model parameter values to minimize the gap between model output and measurement. Some sensors are then used for energy management of the building; thus this work also raise the question of the minimum set of sensors. The third address the characterization of the systems used to control air temperature. For an optimal control logic we must be able to link the effect of the command on the interest variable (air temperature). The demonstration building includes two heating systems : floor heating system (FHS) and fan coil units (FC). A dual flow air handling unit (AHU) is used for air renewal. The last part concerns energy management with the use of a predictive controller boarding one of the identified models. This project intends to anticipate the control of long time response capacitive systems as floor heating through knowledge of future disturbances on a prediction horizon of a few hours (occupation, weather). A reactive control is ensured by the fan coil units. Predictive management is compared to more conventional management strategies in simulation and on-site with the demonstrator building. The originality of this work is to propose a method for the establishment of a full control loop (controller/sensor/actuator) and demonstrate an interest in the predictive management of long response time systems in the building sector.
dc.language.isofr
dc.subjectModèles légers
dc.subjectIdentification
dc.subjectSystèmes énergétiques
dc.subjectContrôle anticipatif
dc.subjectBâtiments
dc.subject.enReduced models
dc.subject.enSystems
dc.subject.enIdentification
dc.subject.enAnticipative control
dc.subject.enBuilding
dc.titleModélisation et instrumentation d'un bâtiment et de ses systèmes pour optimiser sa gestion énergétique
dc.title.enModeling and instrumentation of a building and its systems to optimize energy management
dc.typeThèses de doctorat
dc.subject.halPhysique [physics]/Matière Condensée [cond-mat]/Autre [cond-mat.other]
bordeaux.hal.laboratoriesInstitut de Mécanique et d’Ingénierie de Bordeaux (I2M) - UMR 5295*
bordeaux.institutionUniversité de Bordeaux
bordeaux.institutionBordeaux INP
bordeaux.institutionCNRS
bordeaux.institutionINRAE
bordeaux.institutionArts et Métiers
bordeaux.type.institutionUniversité de Bordeaux
bordeaux.ecole.doctoraleÉcole doctorale des sciences physiques et de l’ingénieur (Talence, Gironde)
hal.identifiertel-01503037
hal.version1
hal.origin.linkhttps://hal.archives-ouvertes.fr//tel-01503037v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Mod%C3%A9lisation%20et%20instrumentation%20d'un%20b%C3%A2timent%20et%20de%20ses%20syst%C3%A8mes%20pour%20optimiser%20sa%20gestion%20%C3%A9nerg%C3%A9tique&rft.atitle=Mod%C3%A9lisation%20et%20instrumentation%20d'un%20b%C3%A2timent%20et%20de%20ses%20syst%C3%A8mes%20pour%20optimiser%20sa%20gestion%20%C3%A9nerg%C3%A9tique&rft.au=VIOT,%20Hugo&rft.genre=unknown


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée