Bioelectronic organ-based sensor for microfluidic real-time analysis of the demand in insulin
dc.rights.license | open | en_US |
hal.structure.identifier | Chimie et Biologie des Membranes et des Nanoobjets [CBMN] | |
dc.contributor.author | PERRIER, Romain | |
hal.structure.identifier | Laboratoire de l'intégration, du matériau au système [IMS] | |
dc.contributor.author | PIROG, Antoine | |
hal.structure.identifier | Chimie et Biologie des Membranes et des Nanoobjets [CBMN] | |
dc.contributor.author | JAFFREDO, Manon | |
hal.structure.identifier | Chimie et Biologie des Membranes et des Nanoobjets [CBMN] | |
dc.contributor.author | GAITAN, Julien | |
hal.structure.identifier | Chimie et Biologie des Membranes et des Nanoobjets [CBMN] | |
dc.contributor.author | CATARGI, Bogdan | |
hal.structure.identifier | Laboratoire de l'intégration, du matériau au système [IMS] | |
dc.contributor.author | RENAUD, Sylvie | |
hal.structure.identifier | Chimie et Biologie des Membranes et des Nanoobjets [CBMN] | |
dc.contributor.author | RAOUX, Matthieu | |
hal.structure.identifier | Chimie et Biologie des Membranes et des Nanoobjets [CBMN] | |
dc.contributor.author | LANG, Jochen | |
dc.date.accessioned | 2020-04-06T13:24:41Z | |
dc.date.available | 2020-04-06T13:24:41Z | |
dc.date.issued | 2018 | |
dc.identifier.issn | 0956-5663 | en_US |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/4119 | |
dc.description.abstractEn | On-line and real-time analysis of micro-organ activity permits to use the endogenous analytical power of cellular signal transduction algorithms as biosensors. We have developed here such a sensor using only a few pancreatic endocrine islets and the avoidance of transgenes or chemical probes reduces bias and procures general usage. Nutrient and hormone-induced changes in islet ion fluxes through channels provide the first integrative read-out of micro-organ activity. Using extracellular electrodes we captured this read-out non-invasively as slow potentials which reflect glucose concentration-dependent (3-15mM) micro-organ activation and coupling. Custom-made PDMS-based microfluidics with platinum black micro-electrode arrays required only some tens of islets and functioned at flow rates of 1-10microl/min which are compatible with microdialysis. We developed hardware solutions for on-line real-time analysis on a reconfigurable Field-Programmable Gate Array (FPGA) that offered resource-efficient architecture and storage of intermediary processing stages. Moreover, real-time adaptive and reconfigurable algorithms accounted for signal disparities and noise distribution. Based on islet slow potentials, this integrated set-up allowed within less than 40mus the discrimination and precise automatic ranking of small increases (2mM steps) of glucose concentrations in real time and within the physiological glucose range. This approach shall permit further development in continuous monitoring of the demand for insulin in type 1 diabetes as well as monitoring of organs-on-chip or maturation of stem-cell derived islets. | |
dc.language.iso | EN | en_US |
dc.subject.en | Diabetes | |
dc.subject.en | Islets | |
dc.subject.en | Continuous glucose monitoring | |
dc.subject.en | Micro-electrode arrays | |
dc.subject.en | On-line real-time analysis | |
dc.subject.en | Field programmable gate array | |
dc.title.en | Bioelectronic organ-based sensor for microfluidic real-time analysis of the demand in insulin | |
dc.title.alternative | Biosensors & bioelectronics | en_US |
dc.type | Article de revue | en_US |
dc.identifier.doi | 10.1016/j.bios.2018.06.015 | |
dc.subject.hal | Chimie/Matériaux | en_US |
bordeaux.journal | Biosens Bioelectron | en_US |
bordeaux.page | 253-259 | en_US |
bordeaux.volume | 117 | en_US |
bordeaux.hal.laboratories | Institut de Chimie & de Biologie des Membranes & des Nano-objets (CBMN) - UMR 5248 | |
bordeaux.institution | Bordeaux INP | en_US |
bordeaux.institution | Université de Bordeaux | en_US |
bordeaux.peerReviewed | oui | en_US |
bordeaux.inpress | non | en_US |
hal.identifier | hal-03184379 | |
hal.version | 1 | |
hal.date.transferred | 2021-03-29T12:09:27Z | |
hal.export | true | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Biosens%20Bioelectron&rft.date=2018&rft.volume=117&rft.spage=253-259&rft.epage=253-259&rft.eissn=0956-5663&rft.issn=0956-5663&rft.au=PERRIER,%20Romain&PIROG,%20Antoine&JAFFREDO,%20Manon&GAITAN,%20Julien&CATARGI,%20Bogdan&rft.genre=article |
Files in this item
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |