Afficher la notice abrégée

dc.contributor.advisorFernandez, Philippe
dc.contributor.authorHENRIQUES DE FIGUEIREDO, Bénédicte
dc.contributor.otherFernandez, Philippe
dc.contributor.otherHatt, Mathieu
dc.date2013-12-17
dc.date.accessioned2020-12-14T21:28:52Z
dc.date.available2020-12-14T21:28:52Z
dc.identifier.urihttp://www.theses.fr/2013BOR22125/abes
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/23326
dc.identifier.nnt2013BOR22125
dc.description.abstractObjectif : Etudier l’impact volumétrique et dosimétrique de l’intégration des données de tomographie par émission de positons (TEP) en radiothérapie (RT) à travers deux modèles cliniques : les cancers oto-rhino-laryngologiques (ORL) et les cancers pulmonaires. Matériel et méthodes : Pour les cancers ORL, après un travail préalable sur fantôme pour mise au point d’une méthode de segmentation automatique par seuillage adaptatif, deux séries de neuf et 15 patients présentant un cancer ORL traité par RT, ont bénéficié d’une TEP respectivement au 18F-Fluorodeoxyglucose (18F-FDG) et au 18F-Fluoromisonidazole (18F-FMISO), traceur de l’hypoxie. Les modifications volumétriques et dosimétriques induites par ces examens ont été analysées. Pour le 18F-FMISO, différents temps d’acquisition et différentes méthodes de segmentation ont également été étudiés. Pour les cancers pulmonaires, l’impact sur la RT d’une TEP-4D au 18F-FDG avec correction des effets de volume partiel (EVP) et application de différentes méthodes de segmentation, a été évalué à travers l’analyse des sept premiers patients inclus dans le protocole PULMOTEP, promu par le CHU de Bordeaux. Résultats : Pour les cancers ORL, la TEP au 18F-FDG a conduit à une réduction des volumes de RT de 40% tout en individualisant des zones de « mismatch » entre TEP et scanner. Pour la TEP au 18F-FMISO, un meilleur contraste des images était retrouvé à 4h. Cependant, les volumes segmentés à 3 et 4h n’étaient pas significativement différents, permettant d’envisager en pratique courante des acquisitions moins tardives à 3h. L’utilisation d’une TEP au 18F-FMISO permettait d’envisager la réalisation d’une « escalade de dose » sur les zones hypoxiques avec une augmentation du taux de probabilité de contrôle tumoral de 18,1% sans augmentation excessive de la toxicité. Pour les cancers pulmonaires, il n’était pas retrouvé d’impact de la correction du mouvement respiratoire, un seul patient sur les sept étudiés présentant une tumeur mobile. Un impact constant de la correction des EVP était par contre retrouvé avec une augmentation de l’activité tumorale maximale de 27% et une diminution des volumes segmentés de 15%.Conclusion : Pour les cancers ORL, la validation de ces résultats nécessite la réalisation d’études cliniques. Pour les cancers pulmonaires, l’utilisation d’une TEP-4D avec correction du mouvement respiratoire doit être envisagée au cas par cas. L’implémentation en clinique de logiciels de correction des EVP semble, par contre, à encourager.
dc.description.abstractEnObjective: To study the impact of Positron Emission Tomography (PET) data on radiotherapy (RT) planning through two clinical models: the head-and-neck cancers (HNC) and the pulmonary cancers. Methods and Materials: For HNC, after a previous phantom study in order to determinate an automatic segmentation method with adaptive thresholding, two series of nine and 15 patients selected for RT, underwent PET with 18F-Fluorodeoxyglucose (FDG) and 18F-Fluoromisonidazole (FMISO). The impact on RT target volumes (TV) and dosimetries was evaluated. For FMISO-PET, several time acquisitions and several segmentation methods were assessed. For pulmonary cancers, the use of a four-dimensional (4D) FDG-PET with partial volume effect (PVE) correction and several segmentation methods was evaluated through the first seven patients enrolled in the PULMOTEP protocol performed by the CHU of Bordeaux. Results: For HNC, FDG-PET led to a RT TV reduction of 40%, with mismatches between PET and CT data. For FMISO-PET images, a better contrast was obtained 4h after FMISO injection. However, segmented volumes obtained at 3 and 4h were not statistically different allowing PET- acquisitions at 3h in routine clinical practice. The use of FMISO-PET allows considering « dose escalation » on hypoxic TV with an increase of tumour control probability by 18,1% without excessive increase of toxicities. For pulmonary cancers, there was no impact of the respiratory motion correction but only one patient on seven presented a mobile tumour. PVE correction had impact on RT TV with an increase of the maximal tumoural activity by 27% and a volume reduction of 15%. Conclusion: For HNC, the validation of these results needs clinical and prospective studies. For pulmonary cancers, the use of 4D-PET must be decided case by case. On the other side, the implementation of automatic software for PVE correction seems interesting.
dc.language.isofr
dc.subjectRadiothérapie
dc.subjectTomographie par émission de positons
dc.subjectEffet de volume partiel
dc.subjectMouvement respiratoire
dc.subjectSegmentation
dc.subject.enRadiotherapy
dc.subject.enPositron emission tomography
dc.subject.enPartial volume effect
dc.subject.enRespiratory motion
dc.subject.enSegmentation
dc.titleEvaluation de l’integration des donnees issues de la tomographie par emission de positons en radiotherapie : application à deux modèles cliniques : les cancers ORL et les cancers pulmonaires
dc.title.enAssessment of the integration of positron emission tomography data in radiotherapy : application through two clinical model the head-and-neck cancers and the pulmonary cancers : the head-and-neck cancers and the pulmonary cancers
dc.typeThèses de doctorat
dc.contributor.jurypresidentVera, Pierre
bordeaux.hal.laboratoriesThèses de l'Université de Bordeaux avant 2014*
bordeaux.institutionUniversité de Bordeaux
bordeaux.type.institutionBordeaux 2
bordeaux.thesis.disciplineSciences, technologie, santé. Neurosciences
bordeaux.ecole.doctoraleÉcole doctorale Sciences de la vie et de la santé (Bordeaux)
star.origin.linkhttps://www.theses.fr/2013BOR22125
dc.contributor.rapporteurCourbon, Frédéric
dc.contributor.rapporteurLaprie, Anne
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Evaluation%20de%20l%E2%80%99integration%20des%20donnees%20issues%20de%20la%20tomographie%20par%20emission%20de%20positons%20en%20radiotherapie%20:%20application%20%C3%A0%&rft.atitle=Evaluation%20de%20l%E2%80%99integration%20des%20donnees%20issues%20de%20la%20tomographie%20par%20emission%20de%20positons%20en%20radiotherapie%20:%20application%20%C3%A0&rft.au=HENRIQUES%20DE%20FIGUEIREDO,%20B%C3%A9n%C3%A9dicte&rft.genre=unknown


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée