dc.description.abstractL’imagerie cardiovasculaire du rongeur par RMN est un véritable défi en ce qui concerne la résolution spatiale et temporelle, le contraste et le temps d’expérience. S’il est aujourd’hui admis que l’acquisition 3D doit être privilégiée chez le petit animal, les temps d’acquisition en 3D sont parfois très longs. Ils doivent pourtant rester compatibles avec les temps d’expérience in vivo. L’objectif de cette thèse était donc de développer de nouvelles méthodes d’imagerie cardiovasculaire 3D rapides pour le petit animal à 4.7 et 9.4 T. Tout d’abord, nous avons développé deux méthodes d’IRM cardiaque 4D (3D résolue dans le temps) à contraste «sang noir». La première méthode est basée sur une séquence TrueFISP (Fast Imaging with Steady-state Precession). Elle a permis d’obtenir le contraste sang noir en une heure d’acquisition. La deuxième méthode est basée sur une séquence FLASH (Fast Low Angle Shot). Elle utilise un gradient bipolaire pour supprimer le signal sanguin et le contraste a été rehaussé en Manganèse. Trente minutes d’acquisition ont alors été suffisantes. Ensuite, une méthode d’angiographie temps-de-vol 3D du corps entier de la souris a été développée. Le contraste vasculaire a été amélioré grâce à l’adjonction de motifs de suppression du signal tissulaire. L’imagerie de l’arbre vasculaire entier a pu être réalisé en moins de 10 minutes. Enfin, une nouvelle méthode d’angiographie fonctionnelle ciné temps-de-vol 4D utilisant une acquisition écho-planar a été développée. Les résultats préliminaires montrent qu’il est possible de diviser par quatre les temps d’acquisition de l’angiographie fonctionnelle classique. Tous ces résultats montrent que l’imagerie cardiovasculaire 3D haute résolution est possible dans des temps d’acquisition raisonnables voire rapides
dc.description.abstractEnCardiovascular MRI in rodents is a real challenge in terms of spatial and temporal resolution, contrast and experiment times. Though it is accepted that 3D acquisition should be preferred in small animals, 3D acquisition times can be very long. However, they must remain compatible with in vivo experiment times. The aim of this thesis was therefore to develop new fast 3D methods of cardiovascular imaging in small animals at 4.7 and 9.4 T. First, two 4D cardiac MRI methods (3D time resolved) were developed in «black-blood» contrast. The first method is based on a TrueFISP sequence (Fast Imaging with Steady-state Precession). It allowed to make black blood contrast in one hour acquisition time. The second method is based on a FLASH sequence (Fast Low Angle Shot). It uses a bipolar gradient to suppress the blood signal and the contrast was enhanced by using Manganese. Thirty minutes were then enough. Next, a time-of-flight angiography method for the whole body of mice was developed. The vascular contrast was improved by adding preparation modules to suppress the signal from tissues. The imaging of the whole arterial tree was realized within less than ten minutes. Finally, a new 4D time-of-flight method of functional cine angiography with echo-planar acquisition was developed. Preliminary results showed that acquisition times could be divided by four compared with those in classical functional angiography. All these results show that high resolution 3D cardiovascular imaging is possible in reasonable or even fast acquisition times.
dc.language.isofr
dc.subjectIRM du Petit animal
dc.subjectImagerie cardiaque
dc.subjectAngiographie
dc.subjectMesure de flux
dc.subject.enSmall animal MRI
dc.subject.enCardiac imaging
dc.subject.enAngiography
dc.subject.enFlow measurement
dc.titleDéveloppements méthodologiques en imagerie cardiovasculaire par résonance magnétique chez le petit animal
dc.title.enMethodological developments in cardiovascular imaging in small animal using magnetic resonance
dc.typeThèses de doctorat
dc.contributor.jurypresidentComment, Arnaud
bordeaux.hal.laboratoriesThèses de l'Université de Bordeaux avant 2014*
bordeaux.institutionUniversité de Bordeaux
bordeaux.type.institutionBordeaux 2
bordeaux.thesis.disciplineSciences, Technologie, Santé. Interface Chimie-Biologie
bordeaux.ecole.doctoraleÉcole doctorale Sciences de la vie et de la santé (Bordeaux)
star.origin.linkhttps://www.theses.fr/2011BOR21833
dc.contributor.rapporteurGillet, Brigitte
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=D%C3%A9veloppements%20m%C3%A9thodologiques%20en%20imagerie%20cardiovasculaire%20par%20r%C3%A9sonance%20magn%C3%A9tique%20chez%20le%20petit%20animal&rft.atitle=D%C3%A9veloppements%20m%C3%A9thodologiques%20en%20imagerie%20cardiovasculaire%20par%20r%C3%A9sonance%20magn%C3%A9tique%20chez%20le%20petit%20animal&rft.au=LEFRAN%C3%87OIS,%20William&rft.genre=unknown


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée