Show simple item record

dc.rights.licenseopenen_US
hal.structure.identifierBioingénierie tissulaire [BIOTIS]
dc.contributor.authorDEMURTAS, Denise
hal.structure.identifierBioingénierie tissulaire [BIOTIS]
dc.contributor.authorALVAREZ-MALMAGRO, Julia
dc.contributor.authorRATHORE, Arvind
dc.contributor.authorMANDAL, Tanushree
hal.structure.identifierBioingénierie tissulaire [BIOTIS]
dc.contributor.authorQUINTERO-JAIME, Andrés Felipe
hal.structure.identifierBioingénierie tissulaire [BIOTIS]
dc.contributor.authorBELOCHAPKINE, Serguei
dc.contributor.authorLIELPETERE, Anna
dc.contributor.authorJAYAKUMAR, Kavita
dc.contributor.authorLEECH, Dónal
dc.contributor.authorSCHUHMANN, Wolfgang
hal.structure.identifierCentre de Recherche Paul Pascal [CRPP]
dc.contributor.authorMANO, Nicolas
hal.structure.identifierBioingénierie tissulaire [BIOTIS]
dc.contributor.authorBOIZIAU, Claudine
ORCID: 0000-0002-0475-2571
IDREF: 85228370
hal.structure.identifierBioingénierie tissulaire [BIOTIS]
dc.contributor.authorMAGNER, Edmond
dc.date.accessioned2025-03-28T08:28:25Z
dc.date.available2025-03-28T08:28:25Z
dc.date.issued2025-10
dc.identifier.issn1567-5394en_US
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/205740
dc.description.abstractThe development of implantable glucose sensors is of significant interest in the management of diabetes. This work focuses on developing an implantable, biocompatible nanoporous gold electrode prototype based on Kapton® for the subcutaneous detection of glucose. The electrodes were first modified with a layer containing glucose oxidase and Os(2,2′-bipyridine) 2 Cl⋅PVI (Os(bpy) 2 Cl PVI). An additional polymeric layer containing poly (2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate) was then added to reduce biofouling and foreign body reaction effects. The modified electrode had a V MAX of 211 ± 13 μA cm -2 and a K Mapp of 6.1 ± 0.8 mM in pseudo physiological conditions, with a linear detection range from 1 to 4 mM and a sensitivity of 28.6 ± 2.1 μA cm -2 mM -1 . In artificial plasma, the response of the sensor was saturated at 3 mM, with a V MAX of 113 ± 10 μA cm -2 and a K Mapp of 2.1 ± 0.4 mM with a linear detection range from 1 to 2.5 mM and a sensitivity of 14.6 ± 3.3 μA cm -2 mM -1 . Mechanical stress testing demonstrated that there was a 40 % reduction of the redox polymer coverage after 320 deformation events, however the catalytic activity was still detectable after 160 events. Minimal cytotoxicity effects of the electrodes were observed. When subcutaneously implanted the electrodes showed fairly good mechanical stability after one week and detachment of the metallic layer on some electrodes after 21 days, probably due to electrode bending. A limited foreign body reaction was observed. These results indicated that the electrodes could be implanted for a period of up to 1 week.
dc.language.isoENen_US
dc.rightsAttribution 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/us/*
dc.subjectforeign body reaction
dc.subjectNanoporous gold
dc.subjectGlucose monitoring
dc.subjectImplantable electrodes
dc.titleDevelopment of flexible nanoporous gold electrodes for the detection of glucose
dc.typeArticle de revueen_US
dc.identifier.doi10.1016/j.bioelechem.2025.108949en_US
dc.subject.halChimie/Chimie analytiqueen_US
dc.subject.halChimie/Autreen_US
bordeaux.journalBioelectrochemistryen_US
bordeaux.page108949en_US
bordeaux.volume165en_US
bordeaux.hal.laboratoriesBioingénierie Tissulaire (BioTis) - U1026en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.institutionCNRSen_US
bordeaux.institutionINSERMen_US
bordeaux.institutionCHU de Bordeauxen_US
bordeaux.institutionInstitut Bergoniéen_US
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
bordeaux.import.sourcecrossref
hal.popularnonen_US
hal.audienceInternationaleen_US
hal.exportfalse
workflow.import.sourcecrossref
dc.rights.ccCC BYen_US
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Development%20of%20flexible%20nanoporous%20gold%20electrodes%20for%20the%20detection%20of%20glucose&rft.atitle=Development%20of%20flexible%20nanoporous%20gold%20electrodes%20for%20the%20detection%20of%20glucose&rft.jtitle=Bioelectrochemistry&rft.date=2025-10&rft.volume=165&rft.spage=108949&rft.epage=108949&rft.eissn=1567-5394&rft.issn=1567-5394&rft.au=DEMURTAS,%20Denise&ALVAREZ-MALMAGRO,%20Julia&RATHORE,%20Arvind&MANDAL,%20Tanushree&QUINTERO-JAIME,%20Andr%C3%A9s%20Felipe&rft.genre=article


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record