Show simple item record

dc.rights.licenseopenen_US
hal.structure.identifierInstitut de Mécanique et d'Ingénierie [I2M]
dc.contributor.authorCHEN AUSTIN, Miguel
hal.structure.identifierÉcole nationale supérieure d'architecture et du paysage de Bordeaux [ENSAP Bordeaux]
hal.structure.identifierInstitut de Mécanique et d'Ingénierie [I2M]
dc.contributor.authorBRUNEAU, Denis
hal.structure.identifierUniversité de Bordeaux [UB]
hal.structure.identifierInstitut de Mécanique et d'Ingénierie [I2M]
dc.contributor.authorSEMPEY, Alain
IDREF: 123978777
hal.structure.identifierInstitut de Mécanique et d'Ingénierie [I2M]
dc.contributor.authorMORA, Laurent
IDREF: 077660870
dc.date.accessioned2024-08-27T12:18:33Z
dc.date.available2024-08-27T12:18:33Z
dc.date.issued2018-12-10
dc.date.conference2018-12-10
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/201324
dc.description.abstractEnData from an experimental investigation, carried out during the summertime (from the end of July to mid-September, 2016), have been statistically analyzed, with the purpose of proposing a post-instalment evaluation technique by assessing the effects that some architectural features have on the indoor environmental conditions in a prototype of Plus Energy House in southwest France. The proposed correlation analysis is tested first, to evaluate its reliability for distinguishing strong from weak correlations. Since the proposed analysis appears to be acceptable, it was used then for studying the relationship between outdoor and indoor environments. Results from the correlation analysis strongly suggest that the impact of direct solar radiation on the indoor environment is well attenuated by the double-glazed windows with blinds implemented in the house.
dc.language.isoENen_US
dc.subject.enStatistical correlation analysis
dc.subject.enAssessment of architectural features
dc.subject.enPost-installment-evaluation
dc.title.enStatistical analysis of architectural features effects on indoor environmental conditions in a plus energy house prototype
dc.typeActes de congrès/Proceedingsen_US
dc.subject.halSciences de l'ingénieur [physics]/Matériauxen_US
bordeaux.hal.laboratoriesInstitut de Mécanique et d’Ingénierie de Bordeaux (I2M) - UMR 5295en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.institutionBordeaux INPen_US
bordeaux.institutionCNRSen_US
bordeaux.institutionINRAEen_US
bordeaux.institutionArts et Métiersen_US
bordeaux.conference.title34th International Conference on Passive and Low Energy Architecture: Smart and Healthy Within the Two-Degree Limiten_US
bordeaux.countrycnen_US
bordeaux.conference.cityHong-Kongen_US
bordeaux.inpressnonen_US
hal.identifierhal-04678916
hal.version1
hal.date.transferred2024-08-27T12:18:36Z
hal.conference.end2018-12-12
hal.popularnonen_US
hal.audienceInternationaleen_US
hal.exporttrue
workflow.import.sourcepubmed
dc.rights.ccPas de Licence CCen_US
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.date=2018-12-10&rft.au=CHEN%20AUSTIN,%20Miguel&BRUNEAU,%20Denis&SEMPEY,%20Alain&MORA,%20Laurent&rft.genre=unknown


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record