Comparison of two Methods for Wavefront Measurement of Terahertz Pulses Combined with 2D Electro-Optic Imaging
Langue
en
Communication dans un congrès avec actes
Ce document a été publié dans
2016 41st International Conference on Infrared, Millimeter, and Terahertz waves (IRMMW-THz), 2016-09-25, Copenhague. 2016
Résumé en anglais
We compare two methods of wavefront analysis of THz pulses associated with a 2D electro-optic imaging system. The first one is the standard Hartmann sensor, and the second one is based on the well-known fact that EO sampling ...Lire la suite >
We compare two methods of wavefront analysis of THz pulses associated with a 2D electro-optic imaging system. The first one is the standard Hartmann sensor, and the second one is based on the well-known fact that EO sampling can record the phase variation of the THz electric field.< Réduire
Mots clés en anglais
Crystals
Electrooptical waveguides
Laser beams
Imaging
Electric fields
Ultrafast optics
Two dimensional displays
Origine
Importé de halUnités de recherche