Effect of temporal pulse shaping on the reduction of laser weld defects in a Pd-Ag-Sn dental alloy.
Langue
en
Article de revue
Ce document a été publié dans
Dental Materials. 2011, vol. 27, n° 3, p. e43-e50
Elsevier
Résumé en anglais
The use of a slow cooling ramp is the only way to significantly reduce the presence of typical defects within the welds for this Pd-based alloy studied.
The use of a slow cooling ramp is the only way to significantly reduce the presence of typical defects within the welds for this Pd-based alloy studied.< Réduire