Measurement and resonance analysis of the 237Np neutron capture cross section
Langue
en
Article de revue
Ce document a été publié dans
Physical Review C. 2012, vol. 85, p. 044616
American Physical Society
Résumé en anglais
The neutron capture cross section of 237Np was measured between 0.7 and 500 eV at the CERN n_TOF facility using the 4π BaF2 Total Absorption Calorimeter. The experimental capture yield was extracted minimizing all the ...Lire la suite >
The neutron capture cross section of 237Np was measured between 0.7 and 500 eV at the CERN n_TOF facility using the 4π BaF2 Total Absorption Calorimeter. The experimental capture yield was extracted minimizing all the systematic uncertainties and was analyzed together with the most reliable transmission data available using the sammy code. The result is a complete set of individual as well as average resonance parameters [D0=0.56(2) eV, 〈Γγ〉=40.9(18) meV, 104S0=0.98(6), R′=9.8(6) fm]. The capture cross section obtained in this work is in overall agreement with the evaluations and the data of Weston and Todd [ Nucl. Sci. Eng. 79 184 (1981)], thus showing sizable differences with respect to previous data from Scherbakov et al. [ J. Nucl. Sci. Technol. 42 135 (2005)] and large discrepancies with data Kobayashi et al. [ J. Nucl. Sci. Technol. 39 111 (2002)]. The results indicate that a new evaluation combining the present capture data with reliable transmission data would allow reaching an accuracy better than 4%, in line with the uncertainty requirements of the nuclear data community for the design and operation of current and future nuclear devices.< Réduire
Origine
Importé de halUnités de recherche