Time Resolved Two Dimensional X-Ray Densitometry of a Two Phase Flow Downstream of a Ventilated Cavity
hal.structure.identifier | University of Michigan [Ann Arbor] | |
dc.contributor.author | MÄKIHARJU, Simo A. | |
hal.structure.identifier | Institut de Recherche de l'Ecole Navale [IRENAV] | |
dc.contributor.author | GABILLET, Céline | |
hal.structure.identifier | Korea Institute of Ocean Science and Technology [KIOST] | |
dc.contributor.author | PAIK, Bu-Geun | |
hal.structure.identifier | Naval Surface Warfare Center | |
dc.contributor.author | CHANG, Natasha A. | |
hal.structure.identifier | University of Michigan [Ann Arbor] | |
dc.contributor.author | PERLIN, Marc | |
hal.structure.identifier | University of Michigan [Ann Arbor] | |
dc.contributor.author | CECCIO, Steven L. | |
dc.date.accessioned | 2021-05-14T09:59:49Z | |
dc.date.available | 2021-05-14T09:59:49Z | |
dc.date.issued | 2013-05 | |
dc.identifier.issn | 0723-4864 | |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/78065 | |
dc.description.abstractEn | To measure the void fraction distribution in gas-liquid flows, a two-dimensional x-ray densitometry system was developed. This system is capable of acquiring a two-dimensional projection with a 225 cm2 area of measurement through 21 cm of water. The images can be acquired at rates on the order of 1 kHz. Common sources of error in x-ray imaging, such as x-ray scatter, image distortion, veiling glare, and beam hardening were considered, and mitigated. The measured average void fraction was compared success fully to that of a phantom target and found to be within 1%. To evaluate the performance of the new system, the flow in and downstream of a ventilated nominally two-dimensional partial cavity was investigated and compared to measurements from dual tip fiber optical probes and high speed video. The measurements were found to have satisfactory agreement for void fractions above 5% of the selected void fraction measurement range. | |
dc.language.iso | en | |
dc.publisher | Springer Verlag (Germany) | |
dc.subject.en | ventilated cavity | |
dc.subject.en | multiphase flow | |
dc.subject.en | x-ray | |
dc.subject.en | densitometry | |
dc.subject.en | void fraction measurement | |
dc.subject.en | bubble probe | |
dc.title.en | Time Resolved Two Dimensional X-Ray Densitometry of a Two Phase Flow Downstream of a Ventilated Cavity | |
dc.type | Article de revue | |
dc.identifier.doi | 10.1007/s00348-013-1561-z | |
dc.subject.hal | Sciences de l'ingénieur [physics]/Mécanique [physics.med-ph]/Mécanique des fluides [physics.class-ph] | |
dc.subject.hal | Physique [physics]/Mécanique [physics]/Mécanique des fluides [physics.class-ph] | |
bordeaux.journal | Experiments in Fluids | |
bordeaux.page | 1561.1-1561.21 | |
bordeaux.volume | 54 | |
bordeaux.hal.laboratories | Institut de Mécanique et d’Ingénierie de Bordeaux (I2M) - UMR 5295 | * |
bordeaux.issue | 7 | |
bordeaux.institution | Université de Bordeaux | |
bordeaux.institution | Bordeaux INP | |
bordeaux.institution | CNRS | |
bordeaux.institution | INRAE | |
bordeaux.institution | Arts et Métiers | |
bordeaux.peerReviewed | oui | |
hal.identifier | hal-01070674 | |
hal.version | 1 | |
hal.origin.link | https://hal.archives-ouvertes.fr//hal-01070674v1 | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Experiments%20in%20Fluids&rft.date=2013-05&rft.volume=54&rft.issue=7&rft.spage=1561.1-1561.21&rft.epage=1561.1-1561.21&rft.eissn=0723-4864&rft.issn=0723-4864&rft.au=M%C3%84KIHARJU,%20Simo%20A.&GABILLET,%20C%C3%A9line&PAIK,%20Bu-Geun&CHANG,%20Natasha%20A.&PERLIN,%20Marc&rft.genre=article |
Fichier(s) constituant ce document
Fichiers | Taille | Format | Vue |
---|---|---|---|
Il n'y a pas de fichiers associés à ce document. |