Afficher la notice abrégée

hal.structure.identifierInstitut de Mécanique et d'Ingénierie de Bordeaux [I2M]
dc.contributor.authorLEDOUX, Yann
IDREF: 102217890
hal.structure.identifierInstitut de Mécanique et d'Ingénierie de Bordeaux [I2M]
dc.contributor.authorMESNARD, Michel
hal.structure.identifierInstituto Politecnico Nacional [Mexico] [IPN]
dc.contributor.authorPEÑALOZA SANDOVAL, Jorge Andrés
hal.structure.identifierInstitut de Mécanique et d'Ingénierie de Bordeaux [I2M]
dc.contributor.authorPERRY, Nicolas
IDREF: 085512125
dc.date.accessioned2021-05-14T09:49:39Z
dc.date.available2021-05-14T09:49:39Z
dc.date.issued2016
dc.identifier.issn2212-8271
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/77235
dc.description.abstractEnFor the surgical treatment of lumbar pathologies, there are essentially two medical devices that are implanted. Spinal fusion by means of a screwed plate generates a loss of intervertebral mobility, whereas a spinal dynamic implant (SPD) allows relativedisplacements and thus preserves the adjacent segments and discs. The main goal of this study is to structure the design and to optimize such SPDs. An analytic model based on geometrical and mechanical relations is set up. The characteristics derive fromdata taken from bibliographical studies. Optimization of the implant characteristics is carried out (materials used, component stiffness, orientation associated with bone tissue degeneration, etc.). To do this, the optimization problem is structured tocombine design variables, the mechanical behavior of the medical device (MD) and functional requirements into a single design model allowing the optimization of the MD behavior through a global index.
dc.language.isoen
dc.publisherELSEVIER
dc.subject.enMulti-criteria decision analysis
dc.subject.enDesign structuring
dc.subject.enDesign optimization
dc.title.enOptimization of a dynamic intervertebral lumbar implant
dc.typeArticle de revue
dc.identifier.doi10.1016/j.procir.2016.05.053
dc.subject.halSciences de l'ingénieur [physics]/Mécanique [physics.med-ph]/Biomécanique [physics.med-ph]
dc.subject.halSciences de l'ingénieur [physics]/Mécanique [physics.med-ph]/Génie mécanique [physics.class-ph]
bordeaux.journalProcedia CIRP
bordeaux.page192-197
bordeaux.volume50
bordeaux.hal.laboratoriesInstitut de Mécanique et d’Ingénierie de Bordeaux (I2M) - UMR 5295*
bordeaux.institutionUniversité de Bordeaux
bordeaux.institutionBordeaux INP
bordeaux.institutionCNRS
bordeaux.institutionINRAE
bordeaux.institutionArts et Métiers
bordeaux.peerReviewedoui
hal.identifierhal-01623791
hal.version1
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-01623791v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Procedia%20CIRP&rft.date=2016&rft.volume=50&rft.spage=192-197&rft.epage=192-197&rft.eissn=2212-8271&rft.issn=2212-8271&rft.au=LEDOUX,%20Yann&MESNARD,%20Michel&PE%C3%91ALOZA%20SANDOVAL,%20Jorge%20Andr%C3%A9s&PERRY,%20Nicolas&rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée