Mostrar el registro sencillo del ítem
Standardized bench test evaluation of coronary stents: Biomechanical characteristics
hal.structure.identifier | Centre Hospitalier Universitaire de Nantes = Nantes University Hospital [CHU Nantes] | |
dc.contributor.author | BONIN, Mickael | |
hal.structure.identifier | ITX - unité de recherche de l'institut du thorax [ITX] | |
dc.contributor.author | GUERIN, Patrice | |
hal.structure.identifier | Centre National de la Recherche Scientifique [CNRS] | |
hal.structure.identifier | Institut de Mécanique et d'Ingénierie [I2M] | |
dc.contributor.author | OLIVE, Jean-Marc | |
hal.structure.identifier | Regenerative Medicine and Skeleton [RMeS] | |
dc.contributor.author | JORDANA, Fabienne | |
hal.structure.identifier | ITX - unité de recherche de l'institut du thorax [ITX] | |
dc.contributor.author | HUCHET, François | |
dc.date.accessioned | 2021-05-14T09:33:45Z | |
dc.date.available | 2021-05-14T09:33:45Z | |
dc.date.issued | 2018-05-18 | |
dc.identifier.issn | 1522-1946 | |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/76077 | |
dc.description.abstractEn | Objectives The purpose of the study was to develop a standardized and global bench test protocol to evaluate the biomechanical characteristics of the most currently used drug-eluting coronary stents. Background The use of coronary stents has contributed to the reduction of cardiovascular mortality but can be associated with specific complications. Improving the biomechanical matching between the stents and the coronary anatomy may reduce these complications. Methods We assessed five commercially available drug-eluting stents: the Absorb, Orsiro, Resolute Onyx, Synergy, and Xience Alpine stents. Following stent deployment at nominal pressure in ambient air, radial elastic recoil and foreshortening were measured. Flexibility (crimped and deployed stents) and longitudinal and radial resistances were evaluated using a mechanical tester. Results Biomechanical characteristics were significantly different for all tested devices (ANOVA, P < 0.01). The Synergy, Orsiro, and Xience Alpine stents presented the lowest elastic recoil. The Synergy and Resolute Onyx stents were the most flexible devices. The Xience Alpine and Absorb stents had the highest longitudinal and radial resistances. Conclusions Drug-eluting coronary stents used in current clinical practice have very different biomechanical characteristics, which should be taken into consideration to select the most appropriate device for each clinical situation. | |
dc.language.iso | en | |
dc.publisher | Wiley | |
dc.title.en | Standardized bench test evaluation of coronary stents: Biomechanical characteristics | |
dc.type | Article de revue | |
dc.identifier.doi | 10.1002/ccd.27912 | |
dc.subject.hal | Sciences de l'ingénieur [physics] | |
dc.subject.hal | Physique [physics]/Mécanique [physics]/Matériaux et structures en mécanique [physics.class-ph] | |
dc.subject.hal | Physique [physics]/Mécanique [physics]/Mécanique des matériaux [physics.class-ph] | |
dc.subject.hal | Sciences du Vivant [q-bio]/Ingénierie biomédicale/Biomatériaux | |
bordeaux.journal | Catheterization and Cardiovascular Interventions | |
bordeaux.page | E465-E470 | |
bordeaux.volume | 92 | |
bordeaux.hal.laboratories | Institut de Mécanique et d’Ingénierie de Bordeaux (I2M) - UMR 5295 | * |
bordeaux.issue | 7 | |
bordeaux.institution | Université de Bordeaux | |
bordeaux.institution | Bordeaux INP | |
bordeaux.institution | CNRS | |
bordeaux.institution | INRAE | |
bordeaux.institution | Arts et Métiers | |
bordeaux.peerReviewed | oui | |
hal.identifier | hal-02910304 | |
hal.version | 1 | |
hal.origin.link | https://hal.archives-ouvertes.fr//hal-02910304v1 | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Catheterization%20and%20Cardiovascular%20Interventions&rft.date=2018-05-18&rft.volume=92&rft.issue=7&rft.spage=E465-E470&rft.epage=E465-E470&rft.eissn=1522-1946&rft.issn=1522-1946&rft.au=BONIN,%20Mickael&GUERIN,%20Patrice&OLIVE,%20Jean-Marc&JORDANA,%20Fabienne&HUCHET,%20Fran%C3%A7ois&rft.genre=article |
Archivos en el ítem
Archivos | Tamaño | Formato | Ver |
---|---|---|---|
No hay archivos asociados a este ítem. |