Afficher la notice abrégée

dc.contributor.advisorCoudière, Yves
dc.contributor.authorDOUANLA LONTSI, Charlie
dc.contributor.otherCoudière, Yves
dc.contributor.otherHubert, Florence
dc.contributor.otherSalmon, Stéphanie
dc.contributor.otherLakkis, Omar
dc.contributor.otherPierre, Charles
dc.contributor.otherBoulakia, Muriel
dc.date2017-11-15
dc.identifier.urihttp://www.theses.fr/2017BORD0752/abes
dc.identifier.urihttps://tel.archives-ouvertes.fr/tel-01647395
dc.identifier.nnt2017BORD0752
dc.description.abstractLes simulations numériques réalistes en électrophysiologie cardiaque ont un coût de calcul extrêmement élevé. Ce coût s’explique en grande partie par la raideur, à la fois en temps et en espace, d’une onde de « potentiel d’action » (PA). Par ailleurs, les phénomènes observés sont très instationnaires et s’étudient en temps long. Une description précise de la dynamique des PA est cruciale pour construire des modèles numériques pertinents d’un point de vue médical ou clinique. Cet aspect fondamental ne peut être contourné dans les études numériques réalistes.La raideur de l’onde de PA ne peut être captée numériquement qu’en ayant recours à des maillages très fins. Ces maillages très fins induisent un coût de calcul très important, et introduisent aussi des erreurs supplémentaires : les systèmes linéaires à résoudre deviennent très mal conditionnés. Au final, les erreurs numériques peuvent être particulièrement grandes dans les simulations alors que leur contrôle est évidemment essentiel pour assurer la fiabilité des résultats. Jusqu’à présent, très peu de résultats sont disponibles pour assurer cette fiabilité. Dans les faits, les erreurs sont la plupart du temps contrôlées par des procédés empiriques. Il existe quelques résultats théoriques étudiant la convergence et la stabilité des schémas numériques associés. En pratique, en plus d'avoir un contrôle de l'erreur sur le potentiel, il est aussi nécessaire d'avoir un contrôle de l’erreur sur des quantités macroscopiques décrivant la dynamique de l’onde de PA : temps d’activation, durée du PA, propriétés de restitution... Ces quantités ont en effet une interprétation physiologique qui permet de caractériser le caractère arythmogène des tissus.Les modèles sont des systèmes d’EDP de réaction-diffusion couplés avec des systèmes d’équations différentielles pouvant être très raides, les modèles ioniques. Ils sont actuellement discrétisés par éléments finis conforme (Lagrange) et par des schémas en temps d’ordre un ou deux. Dans ce travail, nous concevons et évaluons l’intérêt d'utiliser des méthodes d’ordre supérieure pour ces systèmes. Parallèlement nous introduisons d'une part une nouvelle classe de schémas appelé schémas exponentiel Adams Bashforth intégral (IEAB), et d'autre part des schémas Rush Larsen (RL) d'ordre élevé. Ces nouveaux schémas sont des schémas multipas de type exponentiels. Nous montrons qu'ils possèdent des bonnes propriétés de stabilité et permettent de faire face efficacement à la raideur des modèles ioniques. Les schémas que nous proposons sont comparés numériquement (en terme de précision, coût en temps de calcul et stabilité) à plusieurs schémas classiques, ainsi qu'aux schémas exponentiels (RL1, RL2) communément utilisés pour des simulations en électrophysiologie cardiaque. Nous proposons des techniques permettant de calculer avec précision les quantités d’intérêts cliniques (temps d’activation, de récupération, durée du potentiel d’action). Des résultats théoriques de convergence en temps et de convergence globale (espace et temps) sont énoncés et prouvés. Ces résultats sont ensuite illustrés numériquement à travers le modèle monodomaine et les modèles ioniques de Beeler Reuter, de Ten Tusscher et al. L’intérêt d'utiliser des schémas d'ordre élevés est aussi évalué sur des ondes spirales en 2D et 3D.
dc.description.abstractEnRealistic numerical simulations in cardiac electrophysiology have a computational cost of extremely high. This cost is largely explained by the stiffness both in time and space, of the action potential (AP) wave. Moreover, the observed phenomena are very unsteady and are studied in long time. A precise description of the dynamic of AP is crucial for constructing relevant numerical models, from a medical or clinical perspective. This fundamental aspect can not be circumvented in realistic numerical studies.The stiffness of AP wave can only be captured numerically, by using very fine meshes. In addition to the high computational cost, these very fine meshes also introduce additional errors : the linear systems to solve become very badly conditioned. In the end, the numerical errors can be particularly large whereas their control is obviously essential to ensure the reliability of the results. So far very few results are available to ensure this reliability. In practice, the errors are mostly controlled by empirical processes. In practice, in addition of having a control of the error on the potential, it is also necessary to have an error control on macroscopic quantities describing the dynamics of the AP wave : activation time, AP duration, properties of restitution ... These quantities have indeed a physiological interpretation which allows to characterize the arrhythmogenic character of the tissues.The models are systems of reaction diffusion PDE coupled with systems of differential equations that can be very stiffs (ionic models). They are currently discretized by conforming finite elements (Lagrange finite elements methods) and by schemes in time of order one or two. In this work, we design and evaluate the interest of using higher order methods for these systems. At the same time, we introduce on the one hand, a new class of schemes called Integral Exponential Adams Bashforth (IEAB) schemes and, on the other hand, high order Rush Larsen (RL) schemes. These new schemes are exponential time-stepping schemes. We show that they have good stability properties and can efficiently cope with the stiffness of ionic models. The schemes we propose are numerically compared (in terms of accuracy, CPU time and stability) with several classical schemes, as well as with the exponential schemes (RL1, RL2), commonly used for cardiac electrophysiology simulations. We propose good techniques for accurately calculating quantities of clinical interest (activation time, recovery time, duration of action potential). Theoretical results of convergence in time and global convergence (in space and time) are stated and proved. These results are then illustrated numerically through the monodomain model and the ionic models of Beeler Reuter, Ten Tusscher et al. The advantage of using high order schemes is also evaluated on spiral waves in 2D and 3D.
dc.language.isofr
dc.subjectEDO raides (lineaire et non linéaire)
dc.subjectSchémas exponentiels à ordre élevé
dc.subjectÉlectrophysiologie cardiaque
dc.subjectÉquations de réaction diffusion
dc.subjectModèles ioniques; Monodomaine
dc.subjectÉlément finis
dc.subject.enStiff ODEs (linear and nonlinear)
dc.subject.enHigh order time integrating schemes
dc.subject.enCardiac electrophysiology
dc.subject.enReaction diffudion equations
dc.subject.enIonic models; Monodomain
dc.subject.enFinite elements
dc.titleSchémas d'ordre élevé pour des simulations réalistes en électrophysiologie cardiaque
dc.title.enHigh order schemes for realistic simulations in cardiac electrophysiology
dc.typeThèses de doctorat
dc.contributor.jurypresidentHubert, Florence
bordeaux.hal.laboratoriesInstitut de mathématiques de Bordeaux
bordeaux.hal.laboratoriesCARMEN
bordeaux.type.institutionBordeaux
bordeaux.thesis.disciplineMathématiques appliquées et calcul scientifique
bordeaux.ecole.doctoraleÉcole doctorale de mathématiques et informatique (Talence, Gironde)
star.origin.linkhttps://www.theses.fr/2017BORD0752
dc.contributor.rapporteurSalmon, Stéphanie
dc.contributor.rapporteurLakkis, Omar
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Sch%C3%A9mas%20d'ordre%20%C3%A9lev%C3%A9%20pour%20des%20simulations%20r%C3%A9alistes%20en%20%C3%A9lectrophysiologie%20cardiaque&rft.atitle=Sch%C3%A9mas%20d'ordre%20%C3%A9lev%C3%A9%20pour%20des%20simulations%20r%C3%A9alistes%20en%20%C3%A9lectrophysiologie%20cardiaque&rft.au=DOUANLA%20LONTSI,%20Charlie&rft.genre=unknown


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée