Contribution à la caractérisation de composants sub-terahertz
dc.contributor.advisor | Zimmer, Thomas | |
dc.contributor.advisor | Curutchet, Arnaud | |
dc.contributor.advisor | Frégonèse, Sébastien | |
dc.contributor.author | POTÉREAU, Manuel | |
dc.contributor.other | Chakravorty, Anjan | |
dc.contributor.other | Ardouin, Bertrand | |
dc.date | 2015-11-24 | |
dc.identifier.uri | http://www.theses.fr/2015BORD0243/abes | |
dc.identifier.uri | https://tel.archives-ouvertes.fr/tel-01269635 | |
dc.identifier.nnt | 2015BORD0243 | |
dc.description.abstract | La constante amélioration des technologies silicium permet aux transistors bipolaires à hétérojonction (HBT) SiGeC (Silicium-Germanium : Carbone) de concurrencer les composants III-V pour les applications millimétriques et sous-THz (jusqu’à 300GHz). Le cycle de développement de la technologie (caractérisation-modélisation-conception-fabrication) nécessite plusieurs itérations, entraînant des coûts élevés. De plus, les méthodologies de mesure doivent être réévaluées et ajustées pour adresser des fréquences plus élevées. Afin de réduire le nombre d’itérations et de permettre la montée en fréquence de la mesure, un travail de fond sur la première étape, la caractérisation, s’avère indispensable.Pour répondre à cette exigence, une description et une étude des instruments de mesure (VNA) est réalisée dans un premier temps. Un état de l’art des méthodes de calibrage permet de choisir la solution la plus pertinente pour la calibration sur puce valable dans la gamme de fréquences sous-THz. Ensuite, après avoir relevé plusieurs défauts dans la méthode choisie (à savoir la méthode Thru-Reflect-Line : TRL), des solutions sont proposées concernant la modification des calculs des coefficients d’erreur et également en modifiant les standards utilisés durant le calibrage. Finalement, une étude sur les méthodes d’épluchage est réalisée. Une amélioration est proposée par la modification de deux standards évitant le principal problème de l’état de l’art, la surcompensation des composants parasites. | |
dc.description.abstractEn | The continuous improvement in Silicon technologies allows SiGeC (Silicon-Germanium-Carbon) heterojunction bipolar transistors (HBT) to compete with III-V components for millimeter wave and sub-THz (below 300GHz) applications. The technology development cycle (characterization, modeling, design and fabrication) needs several iterations resulting in high costs. Furthermore, the measurement methodologies need to be re-assessed and modified to address higher measurement frequencies. In order to reduce the number of iterations and to allow reliable measurement in the sub-THz band, the characterization procedure has been revisited.First, a description and investigation of the measurement instrument (VNA) has been made. After exploring all possible calibration methods, the best candidate for an “on-wafer” calibration for the sub-THz frequency range has been selected. Then, after analyzing the limits of the chosen calibration method (Thru-Reflect-Line: TRL), workarounds are proposed, by modification of the errors coefficients calculation and by changing the standards used during the calibration process. At last, a study concerning the de-embedding methods is carried out. It is shown, that using two new standards helps to reduce the over-compensation of parasitic components. | |
dc.language.iso | fr | |
dc.subject | Transistor SiGeC | |
dc.subject | Mesures sous pointes | |
dc.subject | Calibrage | |
dc.subject | Épluchage | |
dc.subject | Paramètres S | |
dc.subject | 3D-TRL | |
dc.subject | Calibrage sur puce | |
dc.subject.en | Heterojunction bipolar | |
dc.subject.en | HBT | |
dc.subject.en | SiGeC transistor | |
dc.subject.en | On-wafer measurements | |
dc.subject.en | Calibration | |
dc.subject.en | De-embedding | |
dc.subject.en | S-parameters | |
dc.subject.en | 3D-TRL | |
dc.subject.en | On-wafer calibration | |
dc.title | Contribution à la caractérisation de composants sub-terahertz | |
dc.title.en | Contribution on the characterization of sub THz components | |
dc.type | Thèses de doctorat | |
dc.contributor.jurypresident | Ferrari, Philippe | |
bordeaux.hal.laboratories | Laboratoire de l'intégration du matériau au système (Talence, Gironde) | |
bordeaux.type.institution | Bordeaux | |
bordeaux.thesis.discipline | Electronique | |
bordeaux.ecole.doctorale | École doctorale des sciences physiques et de l’ingénieur (Talence, Gironde) | |
star.origin.link | https://www.theses.fr/2015BORD0243 | |
dc.contributor.rapporteur | Ferrari, Philippe | |
dc.contributor.rapporteur | Quéré, Raymond | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Contribution%20%C3%A0%20la%20caract%C3%A9risation%20de%20composants%20sub-terahertz&rft.atitle=Contribution%20%C3%A0%20la%20caract%C3%A9risation%20de%20composants%20sub-terahertz&rft.au=POT%C3%89REAU,%20Manuel&rft.genre=unknown |
Files in this item
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |