Recherche des désintégrations double bêta avec et sans émission de neutrinos du 82Se vers les états excités du 82Kr dans l'expérience NEMO3 : développement de dispositifs de mesure ultra-sensibles d'émanation du Radon pour l'expérience SuperNEMO
dc.contributor.advisor | Piquemal, Fabrice | |
dc.contributor.advisor | Perrot, Frédéric | |
dc.contributor.author | SOULÉ, Benjamin | |
dc.contributor.other | Busto, José | |
dc.date | 2015-12-02 | |
dc.identifier.uri | http://www.theses.fr/2015BORD0198/abes | |
dc.identifier.uri | ||
dc.identifier.uri | https://tel.archives-ouvertes.fr/tel-01281396 | |
dc.identifier.nnt | 2015BORD0198 | |
dc.description.abstract | Le détecteur NEMO3 a été mis en place au Laboratoire Souterrain de Modane, en 2003, afin de rechercher la décroissance double bêta sans émission de neutrinos (ββ0v). La particularité de cette expérience est d’avoir pu étudier plusieurs isotopes dont le 100Mo, le 82Se, le 96Zr ou le 150Nd. En plus d’avoir placé les meilleures limites sur la demi-vie du processus ββ0v pour ces isotopes, ce détecteur a permis des mesures compétitives de leurs désintégrations ββ2v. Le premier objectif de ce travail a été de mesurer les temps de demi-vie des décroissances ββ2v et ββ0v du 82Se vers l’état excité 0+2 du 82Kr grâce aux données de NEMO3. Ces processus n’ayant pas été observés, seules des limites ont été calculées. Les résultats obtenus pour les deux décroissances sont donc T2 1=2(82Se; 0+1 → 0+2) > 1,29 x 1021 ans et T01=2(82Se; 0+1→ 0+2) > 2,31 x 1022 ans, ce dernier étant la première limite sur cette décroissance. SuperNEMO, successeur de NEMO3, cherchera à atteindre une sensibilité de 1026 ans sur la demivie de la décroissance ββ0v du 82Se. Le Radon étant une source de bruit de fond pour la recherche de cette décroissance, sa concentration dans le détecteur doit être inférieure à 0,15 mBq.m-3. Pour parvenir à un tel niveau, l’émanation de Radon des composants de SuperNEMO doit être contrôlée.Le second objectif de cette thèse a donc été de développer deux dispositifs de mesure d’émanation de Radon. Ces deux systèmes, consistants chacun en une chambre d’émanation associée à un détecteur électrostatique, ont par la suite été étalonnés puis leurs bruits de fond ont été caractérisés. Grâce à leurs sensibilités de quelques mBq.m-3, ces dispositifs ont permis de mesurer les taux d’émanation de Radon de plusieurs matériaux destinés à la construction du détecteur SuperNEMO. | |
dc.description.abstractEn | The NEMO3 detector was installed in the Laboratoire Souterrain de Modane, in 2003, in orderto search for neutrinoless double beta decay (ββ0v). The specificity of this experiment was the possibility to study several isotopes simultaneously. Among them were 100Mo, 82Se, 96Zr or 150Nd. In addition to setting the best limits on these isotopes half-lives for theββ 0v process, the detector performed precise measurements of their 2v ββdecays. The first point of this work was to measure the half-lives of 2v ββand 0v ββdecays of 82Se to the 0+2 excited state of 82Kr using NEMO3 data. Since those processes have not been observed, only limits were set. The resulting half-life limits are T2 1=2(82Se; 0+1 → 0+2) > 1:29 x 1021 yr and T01=2(82Se; 0+1 → 0+2) > 2:31 x 1022 yr. The latest is the first limit ever measured for this decay. SuperNEMO is the successor to NEMO3 and will aim to reach an half-life sensitivity of 1026 yr for the 0v ββdecay of 82Se. Radon being a source of background for the search of this decay, its concentration inside the detector must be less than 0:15 mBq.m-3. To reach this objective, Radon emanation from the detector componants has to be checked. The second goal of this thesis was thus to develop two setups able to measure Radon emanation. Those two devices, each consisting of an emanation chamber associated to an electrostatic detector, were calibrated before their backgrounds were characterized. With a sensitivity of a few mBq.m-3, these setups measured the Radon emanation rate of several materials which will be used for the construction of the SuperNEMO detector. | |
dc.language.iso | fr | |
dc.subject | NEMO3 | |
dc.subject | SuperNEMO | |
dc.subject | Neutrino | |
dc.subject | Décroissance double bêta | |
dc.subject | États excités | |
dc.subject | Radon | |
dc.subject | Émanation | |
dc.subject.en | NEMO3 | |
dc.subject.en | SuperNEMO | |
dc.subject.en | Neutrino | |
dc.subject.en | Double beta decay | |
dc.subject.en | Excited states | |
dc.subject.en | Radon | |
dc.subject.en | Emanation | |
dc.title | Recherche des désintégrations double bêta avec et sans émission de neutrinos du 82Se vers les états excités du 82Kr dans l'expérience NEMO3 : développement de dispositifs de mesure ultra-sensibles d'émanation du Radon pour l'expérience SuperNEMO | |
dc.title.en | Search for double beta decay with and without emission of neutrinos of Se-82 to the excited states of Kr-82 in the NEMO3 experiment : development of apparatuses for ultra-sensitive measurement of Radon emanation for the SuperNEMO experiment | |
dc.type | Thèses de doctorat | |
dc.contributor.jurypresident | Caillon, Jean-Christophe | |
bordeaux.hal.laboratories | Centre d'études nucléaires Bordeaux Gradignan | |
bordeaux.type.institution | Bordeaux | |
bordeaux.thesis.discipline | Astrophysique, plasmas, nucléaire | |
bordeaux.ecole.doctorale | École doctorale des sciences physiques et de l’ingénieur (Talence, Gironde) | |
star.origin.link | https://www.theses.fr/2015BORD0198 | |
dc.contributor.rapporteur | Jollet, Cécile | |
dc.contributor.rapporteur | Lhuillier, David | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Recherche%20des%20d%C3%A9sint%C3%A9grations%20double%20b%C3%AAta%20avec%20et%20sans%20%C3%A9mission%20de%20neutrinos%20du%2082Se%20vers%20les%20%C3%A9tats%20excit%C3%A9s%&rft.atitle=Recherche%20des%20d%C3%A9sint%C3%A9grations%20double%20b%C3%AAta%20avec%20et%20sans%20%C3%A9mission%20de%20neutrinos%20du%2082Se%20vers%20les%20%C3%A9tats%20excit%C3%A9s&rft.au=SOULE%CC%81,%20Benjamin&rft.genre=unknown |
Files in this item
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |