Show simple item record

dc.rights.licenseopenen_US
dc.contributor.authorBLUMEN, E.
dc.contributor.authorDENOYER, A.
dc.contributor.authorGRISE-DULAC, A.
dc.contributor.authorROUSSEAU, A.
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorSCHWEITZER, Cedric
ORCID: 0000-0002-2162-9479
IDREF: 133631583
dc.contributor.authorROZOT, P.
dc.contributor.authorAPTEL, F.
dc.date.accessioned2025-04-15T07:53:07Z
dc.date.available2025-04-15T07:53:07Z
dc.date.issued2025-03-01
dc.identifier.issn1773-0597en_US
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/206202
dc.description.abstractLes progrès récents des techniques chirurgicales et des implants ont transformé la chirurgie de la cataracte en véritable chirurgie réfractive, permettant à de nombreux patients de se passer de correction optique. Les implants « premium » offrent de multiples options pour corriger les amétropies – y compris l’astigmatisme – et les effets de la presbytie. Bien que la chirurgie de la cataracte soit souvent bénéfique chez les patients glaucomateux, la neuropathie optique glaucomateuse peut altérer la qualité de la vision et affecter les résultats des implants premium, en particulier des implants multifocaux. Cette revue concise propose des recommandations pratiques sur l’utilisation des implants premium en fonction du type, du stade et de l’évolutivité du glaucome, en se basant sur les données scientifiques actuelles. Les implants toriques monofocaux sont envisageables pour corriger l’astigmatisme chez les patients glaucomateux, mais nécessitent une évaluation clinique minutieuse. Les implants « monofocaux plus » et certains implants à profondeur de champ étendue (EDOF) peuvent également être envisagés, avec des précautions spécifiques. Les implants multifocaux diffractifs et réfractifs ne sont pas conseillés en cas de glaucome ou en cas d’hypertonie oculaire avec des facteurs de risque d’évolution vers un glaucome. En conclusion, les indications des implants premium chez les patients glaucomateux doivent faire l’objet d’une sélection rigoureuse et individualisée, et d’explications exhaustives.
dc.description.abstractEnRecent advances in surgical techniques and intraocular lens implants have transformed cataract surgery into a true refractive procedure, enabling many patients to forgo optical correction. "Premium" IOL's offer multiple options for correcting refractive errors, including astigmatism, and addressing the effects of presbyopia. While cataract surgery is often beneficial for glaucoma patients, glaucomatous optic neuropathy can impair visual quality and impact the outcomes of premium IOL's, particularly multifocal IOL's. This concise review provides practical recommendations for the use of premium IOL's based on the type, stage and progression profile of glaucoma, supported by current scientific data. Monofocal toric IOL's may be considered to correct astigmatism in glaucoma patients but require careful clinical evaluation. "Monofocal plus" IOL's and certain extended depth of focus (EDOF) IOL's may also be viable options, provided that specific precautions are taken. However, diffractive and refractive multifocal IOL's are not recommended for patients with glaucoma or ocular hypertension with risk factors for development of glaucoma. In conclusion, the indications for premium IOL's in glaucoma patients should include rigorous, individualized selection, along with comprehensive patient counseling.
dc.language.isoFRen_US
dc.subjectGlaucome
dc.subjectCataracte
dc.subjectImplant premium
dc.subject.enCataract
dc.subject.enGlaucoma
dc.subject.enPremium implant
dc.titleUtilisation des implants premium chez les patients glaucomateux : conseils de la Société française du glaucome (SFG) et de la Société de l’association française des implants intra-oculaires et de chirurgie réfractive (SAFIR)
dc.title.enPremium IOL's in glaucoma patients: Guidelines from the French Glaucoma Society (SFG) and the Society of the French Intraocular Lens and Refractive Surgery Association
dc.title.alternativeJ Fr Ophtalmolen_US
dc.typeArticle de revueen_US
dc.identifier.doi10.1016/j.jfo.2025.104431en_US
dc.subject.halSciences du Vivant [q-bio]/Santé publique et épidémiologieen_US
dc.identifier.pubmed39933287en_US
bordeaux.journalJournal Français d'Ophtalmologieen_US
bordeaux.page104431en_US
bordeaux.volume48en_US
bordeaux.hal.laboratoriesBordeaux Population Health Research Center (BPH) - UMR 1219en_US
bordeaux.issue3en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.institutionINSERMen_US
bordeaux.teamLEHA_BPHen_US
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
hal.identifierhal-05034442
hal.version1
hal.date.transferred2025-04-15T07:53:10Z
hal.popularnonen_US
hal.audienceInternationaleen_US
hal.exporttrue
dc.rights.ccPas de Licence CCen_US
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Utilisation%20des%20implants%20premium%20chez%20les%20patients%20glaucomateux%20:%20conseils%20de%20la%20Soci%C3%A9t%C3%A9%20fran%C3%A7aise%20du%20glaucome%20(SFG)%20et%2&rft.atitle=Utilisation%20des%20implants%20premium%20chez%20les%20patients%20glaucomateux%20:%20conseils%20de%20la%20Soci%C3%A9t%C3%A9%20fran%C3%A7aise%20du%20glaucome%20(SFG)%20et%&rft.jtitle=Journal%20Fran%C3%A7ais%20d'Ophtalmologie&rft.date=2025-03-01&rft.volume=48&rft.issue=3&rft.spage=104431&rft.epage=104431&rft.eissn=1773-0597&rft.issn=1773-0597&rft.au=BLUMEN,%20E.&DENOYER,%20A.&GRISE-DULAC,%20A.&ROUSSEAU,%20A.&SCHWEITZER,%20Cedric&rft.genre=article


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record