Show simple item record

dc.contributor.advisorJérôme Saracco
dc.contributor.advisorVincent Couallier
hal.structure.identifierInstitut de Mathématiques de Bordeaux [IMB]
dc.contributor.authorCLAUDIO, Karim
dc.contributor.otherNikolaos Limnios [Président]
dc.contributor.otherAnne Ruiz-Gazen [Rapporteur]
dc.contributor.otherAnne Gégout-Petit [Rapporteur]
dc.contributor.otherYves Le Gat
dc.contributor.otherCamelia Goga
dc.contributor.otherXavier Litrico
dc.date.accessioned2024-04-04T03:18:20Z
dc.date.available2024-04-04T03:18:20Z
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/194394
dc.identifier.nnt2014BORD0482
dc.description.abstractL’évolution de l’équipement des réseaux d’eau potable a considérablement amélioré le pilotage de ces derniers. Le telérelevé des compteurs d’eau est sans doute la technologie qui a créé la plus grande avancée ces dernières années dans la gestion de l’eau, tant pour l’opérateur que pour l’usager. Cette technologie a permis de passer d’une information le plus souvent annuelle sur les consommations (suite à la relève manuelle des compteurs d’eau) à une information infra-journalière. Mais le télérelevé, aussi performant soit-il, a un inconvénient : son coût. L’instrumentation complète d’un réseau engendre des investissements que certains opérateurs ne peuvent se permettre. Ainsi la création d’un échantillon de compteurs à équiper permet d’estimer la consommation totale d’un réseau tout en minimisant les coûts d’investissement. Cet échantillon doit être construit de façon intelligente de sorte que l’imprécision liée à l’estimation ne nuise pas à l’évaluation des consommations. Une connaissance précise sur les consommations d’eau permet de quantifier les volumes perdus en réseau. Mais, même dans le cas d’une évaluation exacte des pertes, cela ne peut pas suffire à éliminer toutes les fuites sur le réseau. En effet, si le réseau de distribution d’eau potable est majoritairement enterré, donc invisible, il en va de même pour les fuites. Une fraction des fuites est invisible et même indétectable par les techniques actuelles de recherche de fuites, et donc irréparable. La construction d’un modèle de fuite multi-états permet de décomposer le débit de fuite suivant les différents stades d’apparition d’une fuite : invisible et indétectable, invisible mais détectable par la recherche de fuite et enfin visible en surface. Ce modèle, de type semi-markovien, prend en compte les contraintes opérationnelles, notamment le fait que nous disposons de données de panel. La décomposition du débit de fuite permet de fait une meilleure gestion du réseau en ciblant et adaptant les actions de lutte contre les fuites à mettre en place en fonction de l’état de dégradation du réseau.
dc.description.abstractEnThe evolution of equipment on drinking water networks has considerably bettered the monitoring of these lasts. Automatic meter reading (AMR) is clearly the technology which has brought the major progress these last years in water management, as for the operator and the end-users. This technology has allowed passing from an annual information on water consumption (thanks to the manual meter reading) toan infra-daily information. But as efficient as AMR can be, it has one main inconvenient : its cost. A complete network instrumentation generates capital expenditures that some operators can’t allowed themselves. The constitution of a sample of meters to equip enables then to estimate the network total consumption while minimizing the investments. This sample has to be built smartly so the inaccuracy of the estimator shouldn’t be harmful to the consumption estimation. A precise knowledge on water consumption allowsquantifying the water lost volumes on the network. But even an exact assessment of losses is still not enough to eliminate all the leaks on the network. Indeed, if the water distribution network is buried, and so invisible, so do the leaks. A fraction of leaks are invisible and even undetectable by the current technologies of leakage control, and so these leaks are un-reparable. The construction of a multi-state model enables us to decompose the leakage flow according to the different stages of appearance of a leak : invisible and undetectable, invisible but detectable with leakage control and finally detectable. This semi-Markovian model takes into account operational constrains, in particular the fact that we dispose of panel data. The leakage flow decomposition allows a better network monitoring but targeting and adapting the action of leakage reduction to set up according to the degradation state of the network.
dc.language.isofr
dc.subjectGestion des réseaux d’eau potable
dc.subjectModèle semi-markovien
dc.subjectDécomposition du débit de fuite
dc.subjectTélérelevé des compteurs
dc.subjectEstimation des consommations
dc.subjectÉchantillonnage par sondage stratifié
dc.subject.enDrinking water network management
dc.subject.enSemi-Markovian model
dc.subject.enLeakage flow decomposition
dc.subject.enAutomatic meter reading
dc.subject.enWater consumption estimation
dc.subject.enStratified sample
dc.titleMise en place d'un modèle de fuite multi-états en secteur hydraulique partiellement instrumenté
dc.title.enMastering losses on drinking water network
dc.typeThèses de doctorat
dc.subject.halInformatique [cs]/Architectures Matérielles [cs.AR]
bordeaux.hal.laboratoriesInstitut de Mathématiques de Bordeaux (IMB) - UMR 5251*
bordeaux.institutionUniversité de Bordeaux
bordeaux.institutionBordeaux INP
bordeaux.institutionCNRS
bordeaux.type.institutionUniversité de Bordeaux
bordeaux.ecole.doctoraleÉcole doctorale de mathématiques et informatique (Talence, Gironde ; 1991-....)
hal.identifiertel-01158075
hal.version1
hal.origin.linkhttps://hal.archives-ouvertes.fr//tel-01158075v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Mise%20en%20place%20d'un%20mod%C3%A8le%20de%20fuite%20multi-%C3%A9tats%20en%20secteur%20hydraulique%20partiellement%20instrument%C3%A9&rft.atitle=Mise%20en%20place%20d'un%20mod%C3%A8le%20de%20fuite%20multi-%C3%A9tats%20en%20secteur%20hydraulique%20partiellement%20instrument%C3%A9&rft.au=CLAUDIO,%20Karim&rft.genre=unknown


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record