Afficher la notice abrégée

hal.structure.identifierInstitut des sciences analytiques et de physico-chimie pour l'environnement et les materiaux [IPREM]
dc.contributor.authorLABEYRIE, Laurie
hal.structure.identifierInstitut des sciences analytiques et de physico-chimie pour l'environnement et les materiaux [IPREM]
dc.contributor.authorVALLVERDU, Germain
hal.structure.identifierInstitut de Chimie de la Matière Condensée de Bordeaux [ICMCB]
dc.contributor.authorMICHAU, Dominique
hal.structure.identifierNutrition, Métabolisme, Aquaculture [NuMéA]
dc.contributor.authorFONTAGNÉ-DICHARRY, Stéphanie
hal.structure.identifierInstitut des sciences analytiques et de physico-chimie pour l'environnement et les materiaux [IPREM]
dc.contributor.authorMOUNICOU, Sandra
dc.date.accessioned2023-11-20T17:25:56Z
dc.date.available2023-11-20T17:25:56Z
dc.date.issued2023
dc.identifier.issn0026-265X
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/185847
dc.description.abstractEnThe quantitative imaging of trace elements in biological samples can bring information on their assimilation pathways and help understanding their toxicity or essentiality. This study presents the development of two quantitative LA-ICP MS methodologies and their comparison for Se, Hg, Cu, Zn and Mo imaging in rainbow trout. The first method is based on spiked polymer films (dextran) allowing internal standardization with Ge and Te. The second method relies on the matrix-matched standards (MMS) methodology, with homogenized and spiked trout muscle and calf liver. For Se, Cu, Zn and Mo, linear regressions with correlation coefficient above 0.994 were obtained by LA-ICP MS analysis for both methods. For Hg, only MMS calibration provided linear regression as polymer films exhibited Hg unstable signals during LA-ICP MS analysis. Element concentrations spiked in muscle and liver MMS were also confirmed by ICP MS and used to validate the polymer films method as values obtained for Se, Hg, Mo and Cu were in good agreement. While LODs of polymer film method were in the range of 0.06–0.6 µg.g−1 for Cu, Se, Mo, and 5 µg.g−1 for Zn, values were higher for MMS method (from 0.06 (Mo) to 2.2 (Cu) µg.g−1, and 30 of µg.g−1 for Zn). Particular attention has been paid to sample embedding and water was found to minimize internal standard response bias. Both methods were then applied to the quantitative mapping of these five elements in rainbow trout fry supplemented or not with organic forms of Se and Hg through parental and direct feeding. Calibrations were analysed before and after sample imaging evidencing a lower bias between the two quantifications with polymer films calibration than with MMS calibration. For the first time, elements concentrations were determined at 60 × 60 µm spatial resolution in specific tissues or organs of entire fry. Depending on the element, polymer films quantification was in agreement with trout muscle (Cu, Se) or with calf liver MMS quantification (Zn).
dc.description.sponsorshipE2S - ANR-16-IDEX-0002
dc.language.isoen
dc.publisherElsevier
dc.subject.enLA-ICP MS
dc.subject.enbioimaging
dc.subject.enselenium
dc.subject.enmercury
dc.subject.enquantification
dc.subject.entrout fry
dc.title.enDevelopment of polymer films and biological matrices standards for selenium, mercury and endogenous elements quantitative LA-ICP MS imaging in entire rainbow trout fry
dc.typeArticle de revue
dc.identifier.doi10.1016/j.microc.2023.109204
dc.subject.halChimie/Chimie analytique
dc.subject.halSciences du Vivant [q-bio]/Biochimie, Biologie Moléculaire/Biochimie [q-bio.BM]
dc.subject.halSciences du Vivant [q-bio]/Ingénierie des aliments
bordeaux.journalMicrochemical Journal
bordeaux.page109204
bordeaux.volume194
bordeaux.hal.laboratoriesInstitut de Chimie de la Matière Condensée de Bordeaux (ICMCB) - UMR 5026*
bordeaux.institutionUniversité de Bordeaux
bordeaux.institutionBordeaux INP
bordeaux.institutionCNRS
bordeaux.peerReviewedoui
hal.identifierhal-04197105
hal.version1
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-04197105v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Microchemical%20Journal&rft.date=2023&rft.volume=194&rft.spage=109204&rft.epage=109204&rft.eissn=0026-265X&rft.issn=0026-265X&rft.au=LABEYRIE,%20Laurie&VALLVERDU,%20Germain&MICHAU,%20Dominique&FONTAGN%C3%89-DICHARRY,%20St%C3%A9phanie&MOUNICOU,%20Sandra&rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée