Show simple item record

hal.structure.identifierInstitut National de Recherche et d'Analyse Physico-Chimique [INRAP]
hal.structure.identifierLaboratoire Ondes et Matière d'Aquitaine [LOMA]
dc.contributor.authorSOUSSOU, A.
hal.structure.identifierLaboratoire Ondes et Matière d'Aquitaine [LOMA]
dc.contributor.authorGAMMOUDI, I.
hal.structure.identifierLaboratoire Ondes et Matière d'Aquitaine [LOMA]
dc.contributor.authorMOROTÉ, F.
hal.structure.identifierLaboratoire Ondes et Matière d'Aquitaine [LOMA]
dc.contributor.authorMATHELIÉ-GUINLET, M.
hal.structure.identifierLaboratoire de Microélectronique et Instrumentations [Monastir]
dc.contributor.authorKALBOUSSI, A.
hal.structure.identifierInstitut National de Recherche et d'Analyse Physico-Chimique [INRAP]
dc.contributor.authorBACCAR, Z.M.
hal.structure.identifierLaboratoire Ondes et Matière d'Aquitaine [LOMA]
dc.contributor.authorCOHEN-BOUHACINA, T.
hal.structure.identifierLaboratoire Ondes et Matière d'Aquitaine [LOMA]
dc.contributor.authorGRAUBY-HEYWANG, C.
dc.date.issued2016
dc.identifier.issn1877-7058
dc.description.abstractEnAn amperometric biosensor based on tyrosinase immobilized on the sensor surface has been used for the detection of polyphenols extracted from green tea. The immobilization was ensured by the crosslinking method on thins films of CoAlSO 4 layered double hydroxide recovering screen-printed gold electrodes. Electrochemical measurements show that this biosensor is able to detect tea polyphenols by following the reduction of compounds enzymatically generated. Its response is linear in the concentration range of [0-2,4 µM] with high sensitivity and stability, since it retains 90% of its original response after 20 days.
dc.language.isoen
dc.publisherElsevier
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/
dc.subject.enamperometric biosensor
dc.subject.enlayered double hydroxide
dc.subject.entyrosinase
dc.subject.enatomic force microscopy
dc.title.enAmperometric Polyphenol Biosensor Based on Tyrosinase Immobilization on CoAl Layered Double Hydroxide Thins Films
dc.typeArticle de revue
dc.identifier.doi10.1016/j.proeng.2016.11.371
dc.subject.halChimie/Chimie analytique
dc.subject.halSciences du Vivant [q-bio]/Biotechnologies
bordeaux.journalProcedia Engineering
bordeaux.page1131-1134
bordeaux.volume168
bordeaux.peerReviewedoui
hal.identifierhal-01477810
hal.version1
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-01477810v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Procedia%20Engineering&rft.date=2016&rft.volume=168&rft.spage=1131-1134&rft.epage=1131-1134&rft.eissn=1877-7058&rft.issn=1877-7058&rft.au=SOUSSOU,%20A.&GAMMOUDI,%20I.&MOROT%C3%89,%20F.&MATHELI%C3%89-GUINLET,%20M.&KALBOUSSI,%20A.&rft.genre=article


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record