Afficher la notice abrégée

hal.structure.identifierBen-Gurion University of the Negev [BGU]
dc.contributor.authorISAACS, Sivan
hal.structure.identifierLaboratoire Ondes et Matière d'Aquitaine [LOMA]
hal.structure.identifierChimie et Biologie des Membranes et des Nanoobjets [CBMN]
dc.contributor.authorHARTÉ, Etienne
hal.structure.identifierChimie et Biologie des Membranes et des Nanoobjets [CBMN]
dc.contributor.authorALVES, Isabel
hal.structure.identifierBen-Gurion University of the Negev [BGU]
dc.contributor.authorABDULHALIM, Ibrahim
dc.date.issued2019-03-02
dc.identifier.issn1424-8220
dc.description.abstractEnPlasmon waveguide resonance (PWR) sensors exhibit narrow resonances at the two orthogonal polarizations, transverse electric (TE) and transverse magnetic (TM), which are narrower by almost an order of a magnitude than the standard surface plasmon resonance (SPR), and thus the figure of merit is enhanced. This fact is useful for measuring optical anisotropy of materials on the surface and determining the orientation of molecules with high resolution. Using the diverging beam approach and a liquid crystal retarder, we present experimental results by simultaneous detection of TE and TM polarized resonances as well as using fast higher contrast serial detection with a variable liquid crystal retarder. While simultaneous detection makes the system simpler, a serial one has the advantage of obtaining a larger contrast of the resonances and thus an improved signal-to-noise ratio. Although the sensitivity of the PWR resonances is smaller than the standard SPR, the angular width is much smaller, and thus the figure of merit is improved. When the measurement methodology has a high enough angular resolution, as is the one presented here, the PWR becomes advantageous over other SPR modes. The possibility of carrying out exact numerical simulations for anisotropic molecules using the 4 × 4 matrix approach brings another advantage of the PWR over SPR on the possibility of extracting the orientation of molecules adsorbed to the surface. High sensitivity of the TE and TM signals to the anisotropic molecules orientation is found here, and comparison to the experimental data allowed detection of the orientation of lipids on the sensor surface. The molecular orientations cannot be fully determined from the TM polarization alone as in standard SPR, which underlines the additional advantage of the PWR technique.
dc.language.isoen
dc.publisherMDPI
dc.subject.enliquid crystal
dc.subject.ensurface plasmon resonance
dc.subject.enplasmon waveguide resonance
dc.subject.enbiosensors
dc.title.enImproved Detection of Plasmon Waveguide Resonance Using Diverging Beam, Liquid Crystal Retarder, and Application to Lipid Orientation Determination
dc.typeArticle de revue
dc.identifier.doi10.3390/s19061402
dc.subject.halSciences de l'ingénieur [physics]/Optique / photonique
dc.subject.halChimie/Matériaux
bordeaux.journalSensors
bordeaux.page1402 (1-12)
bordeaux.volume19
bordeaux.issue6
bordeaux.peerReviewedoui
hal.identifierhal-02117290
hal.version1
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-02117290v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Sensors&rft.date=2019-03-02&rft.volume=19&rft.issue=6&rft.spage=1402%20(1-12)&rft.epage=1402%20(1-12)&rft.eissn=1424-8220&rft.issn=1424-8220&rft.au=ISAACS,%20Sivan&HART%C3%89,%20Etienne&ALVES,%20Isabel&ABDULHALIM,%20Ibrahim&rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée