Modélisation et régulation de la glycémie dans la maladie du diabète
dc.contributor.advisor | Henry, David | |
dc.contributor.advisor | Cieslak, Jérôme | |
dc.contributor.author | CASSANY, Louis | |
dc.contributor.other | Henry, David | |
dc.contributor.other | Cieslak, Jérôme | |
dc.contributor.other | Cocquempot, Vincent | |
dc.contributor.other | Rodrigues, Mickaël | |
dc.contributor.other | Gucik-Derigny, David | |
dc.contributor.other | Thomassin, Magalie | |
dc.contributor.other | Nicolescu-Catargi, Bogdan | |
dc.contributor.other | Theilliol, Didier | |
dc.date | 2022-07-18 | |
dc.date.accessioned | 2022-09-23T23:35:53Z | |
dc.date.available | 2022-09-23T23:35:53Z | |
dc.identifier.uri | http://www.theses.fr/2022BORD0224/abes | |
dc.identifier.uri | ||
dc.identifier.uri | https://tel.archives-ouvertes.fr/tel-03783467 | |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/148326 | |
dc.identifier.nnt | 2022BORD0224 | |
dc.description.abstract | Aujourd'hui, les technologies de mesure CGM (Continuous Glucose Monitoring) et d’insulinothérapie par pompe à insuline révolutionnent le traitement du diabète. Les capteurs sont toutefois limités à la mesure de glucose et les algorithmes d’insulinothérapie sont ainsi limités. L’action menée par le consortium de recherche constitué de l'IMS (Laboratoire de l'Intégration du Matériau au Système), du CBMN (laboratoire de Chimie et Biologie des Membranes et Nano-objets) et du CHU (Centre Hospitalier Universitaire) de Bordeaux, rassemble des diabétologues et des spécialistes de la biologie des îlots pancréatiques, de la micro-électronique et de l’automatique, pour développer un nouveau dispositif de mesure et de contrôle de glycémie qui inclut la prise en compte de différentes hormones dans la mesure. Les travaux de cette thèse s’inscrivent dans ce contexte. Le travail de thèse consiste à utiliser les outils de la commande robuste pour établir de nouveaux algorithmes d’insulinothérapie (contrôle de pompe à insuline) permettant de s’adapter aux grandes variabilités des patients (âge, poids...) et des conditions de vie (sport, sommeil, repas de famille, etc.). La démonstration « in silico » des solutions développées est effectuée à l’aide du simulateur UVA/PADOVA, simulateur Matlab/Simulink certifié par la FDA (Food and Drug Administration) pour les essais pré-cliniques. | |
dc.description.abstractEn | Recent advancements in CGM sensors (Continuous Glucose Monitoring) and insulin pumps considerably improved the treatment of diabetes. However, CGM sensors can only measure the blood glucose level, limiting the insulin therapy algorithms. The IMS laboratory (Integration: from Material to Systems), the CBMN laboratory (Chemistry, Biology of Membranes and Nano-objects) and the CHU (University Hospital Center) gather specialists in diabetes, pancreatic islet biology, microelectronics and automatic control in order to develop new solutions for glycemic measurement and regulation for patients with diabetes. The work of this thesis falls within this context. The goal is to use the tools of the robust control theory in order to develop new insulinotherapy algorithms that can adapt to the physiological variability of the patient (age, weight...). These algorithms will be evaluated in the UVA/Padova simulator, currently the only simulator approved by the FDA (Food and Drug Administration) for in silico pre-clinical tests. | |
dc.language.iso | fr | |
dc.subject | Automatique | |
dc.subject | Modélisation | |
dc.subject | Commande robuste | |
dc.subject | Commande H∞ | |
dc.subject.en | Control theory | |
dc.subject.en | Modelisation | |
dc.subject.en | Robust control | |
dc.subject.en | H∞ control | |
dc.title | Modélisation et régulation de la glycémie dans la maladie du diabète | |
dc.title.en | Glycemia modelisation and regulation in type-1 diabetes | |
dc.type | Thèses de doctorat | |
dc.contributor.jurypresident | Cocquempot, Vincent | |
bordeaux.hal.laboratories | Laboratoire de l'intégration du matériau au système (Talence, Gironde) | |
bordeaux.type.institution | Bordeaux | |
bordeaux.thesis.discipline | Automatique, Productique, Signal et Image, Ingénierie cognitique | |
bordeaux.ecole.doctorale | École doctorale des sciences physiques et de l’ingénieur (Talence, Gironde) | |
star.origin.link | https://www.theses.fr/2022BORD0224 | |
dc.contributor.rapporteur | Cocquempot, Vincent | |
dc.contributor.rapporteur | Rodrigues, Mickaël | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Mod%C3%A9lisation%20et%20r%C3%A9gulation%20de%20la%20glyc%C3%A9mie%20dans%20la%20maladie%20du%20diab%C3%A8te&rft.atitle=Mod%C3%A9lisation%20et%20r%C3%A9gulation%20de%20la%20glyc%C3%A9mie%20dans%20la%20maladie%20du%20diab%C3%A8te&rft.au=CASSANY,%20Louis&rft.genre=unknown |
Files in this item
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |