dc.description.abstractEnLight transmission aggregometry (LTA) is still considered as the “gold standard” for platelet function assessment but, as acompletely manual technology, it is labour intensive. This challenge can be overcome by performing platelet aggregometry in anautomated method on a routine coagulation analyzer. We aimed to compare and correlate results obtained from a traditional manual LTA solution realized in our Reference Center with an optimized automated system using CE-marked agonist reagents. Platelet rich plasma from patients with suspected platelet disorders, von Willebrand disease or antiplatelet therapy have been assessed using a wide range of agonist concentrations. Results were expressed as Maximal Platelet Aggregation and correlation was analyzed using the Passing and Bablok regression test. Platelet aggregometry studies were performed in 49 samples. Maximal aggregation response with ADP (0.5-10 μM), collagen (2 mg/μL), ristocetin (1.2 mg/mL) and arachidonic acid (1 mM) agonists showed significant correlation between the two aggregometers (p< .001). We observed a more variable response using lowconcentrations of ADP (≤5 μM). Moreover, we also noted discrepancies with the low dose of ristocetin, showing excessive paradoxical agglutination with the CS-2500, suggesting that a lower ristocetin dose should be used with this system. These data show that CS-2500 has the advantages of a walk-away technology and the use of CE-marked reagents also permit the possibility of an easier certification.
dc.language.isoENen_US
dc.subjectArticle CLINIQUE
dc.title.enAssessment of light transmission aggregometry on the routine coagulation analyzer Sysmex CS-2500 using CE-marked agonists from Hyphen Biomed
dc.typeArticle de revueen_US
dc.identifier.doi10.1080/09537104.2018.1528346en_US
dc.subject.halSciences du Vivant [q-bio]/Médecine humaine et pathologieen_US
bordeaux.journalPlateletsen_US
bordeaux.page540–542en_US
bordeaux.volume30en_US
bordeaux.hal.laboratoriesBiologie des maladies cardiovasculaires - U1034en_US
bordeaux.issue4en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
hal.identifierhal-03007492
hal.version1
hal.date.transferred2020-11-16T12:35:05Z
hal.exporttrue
bordeaux.COinSctx_ver=Z39.88-2004&amp;rft_val_fmt=info:ofi/fmt:kev:mtx:journal&amp;rft.jtitle=Platelets&amp;rft.date=2019-05&amp;rft.volume=30&amp;rft.issue=4&amp;rft.spage=540%E2%80%93542&amp;rft.epage=540%E2%80%93542&amp;rft.eissn=0953-7104,%201369-1635&amp;rft.issn=0953-7104,%201369-1635&amp;rft.au=BRET,%20V.-E.&amp;POUGAULT,%20B.&amp;GUY,%20A.&amp;CASTET,%20S.&amp;HUGUENIN,%20Y.&amp;rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée