Afficher la notice abrégée

hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorBOYER, S.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorWILSON, J.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorDASSIE, D.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorHAAS, B.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorAICHE, M.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorBARREAU, G.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorCZAJKOWSKI, S.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorGROSJEAN, C.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorPETIT, M.
hal.structure.identifierDépartement d'Astrophysique, de physique des Particules, de physique Nucléaire et de l'Instrumentation Associée [DAPNIA]
dc.contributor.authorGUNSING, F.
dc.contributor.editorAgata Olariu
dc.contributor.editorKristina Stenstyrom
dc.contributor.editorRagnar Hellborg
dc.date.issued2005
dc.date.conference2002-09-02
dc.description.abstractEnIn this contribution we describe the measurement of the efficiency and response functions of a liquid scintillator dectector (C$-{6}$D$_{6}$) using scaled gamma ray sources and (p, $\gamma$) reactions with light nuclei. The measured functions have also been compared to functions calculated using Monte Carlo simulation techniques. If these two functions are known over a wide range of gamma energy, then gamma cascades generated in a (n,$\gamma$) capture reaction can be counted via a method that is independent of their pathways provide the detector response is weighted by functions that force the detection efficiency to be proportional to the emitted gamma ray energy.
dc.language.isoen
dc.publisherEditura Academiei
dc.source.titleProceedings of the International Conference on Applications of High Precision Atomic & Nuclear Methods
dc.title.enEfficiency and response function of a C$-{6}$D$_{6}$ detector used for (n,$\gamma$) capture reaction cross-section measurements
dc.typeAutre communication scientifique (congrès sans actes - poster - séminaire...)
dc.subject.halPhysique [physics]/Physique Nucléaire Expérimentale [nucl-ex]
bordeaux.page289-294
bordeaux.countryRO
bordeaux.title.proceedingProceedings of the International Conference on Applications of High Precision Atomic & Nuclear Methods
bordeaux.conference.cityNeptun
bordeaux.peerReviewedoui
hal.identifierin2p3-00103457
hal.version1
hal.invitednon
hal.proceedingsoui
hal.conference.end2002-09-06
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//in2p3-00103457v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.btitle=Proceedings%20of%20the%20International%20Conference%20on%20Applications%20of%20High%20Precision%20Atomic%20&%20Nuclear%20Methods&rft.date=2005&rft.spage=289-294&rft.epage=289-294&rft.au=BOYER,%20S.&WILSON,%20J.&DASSIE,%20D.&HAAS,%20B.&AICHE,%20M.&rft.genre=conference


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée