Afficher la notice abrégée

dc.rights.licenseopenen_US
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorDE COURSON DE LA VILLENEUVE, Hugues
dc.contributor.authorFERRER, Loic
dc.contributor.authorCANE, Gregoire
dc.contributor.authorVERCHERE, Eric
dc.contributor.authorSESAY, Musa
dc.contributor.authorNOUETTE-GAULAIN, Karine
hal.structure.identifierBiologie des maladies cardiovasculaires = Biology of Cardiovascular Diseases
dc.contributor.authorBIAIS, Matthieu
dc.date.accessioned2020-11-10T10:58:45Z
dc.date.available2020-11-10T10:58:45Z
dc.date.issued2019-10
dc.identifier.issn2110-5820en_US
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/12193
dc.description.abstractEnBACKGROUND: Many maneuvers assessing fluid responsiveness (minifluid challenge, lung recruitment maneuver, end-expiratory occlusion test, passive leg raising) are considered as positive when small variations in cardiac index, stroke volume index, stroke volume variation or pulse pressure variation occur. Pulse contour analysis allows continuous and real-time cardiac index, stroke volume, stroke volume variation and pulse pressure variation estimations. To use these maneuvers with pulse contour analysis, the knowledge of the minimal change that needs to be measured by a device to recognize a real change (least significant change) has to be studied. The aim of this study was to evaluate the least significant change of cardiac index, stroke volume index, stroke volume variation and pulse pressure variation obtained using pulse contour analysis (ProAQT®, Pulsion Medical System, Germany). METHODS: In this observational study, we included 50 mechanically ventilated patients undergoing neurosurgery in the operating room. Cardiac index, stroke volume index, pulse pressure variation and stroke volume variation obtained using ProAQT® (Pulsion Medical System, Germany) were recorded every 12 s during 15-min steady-state periods. Least significant changes were calculated every minute. RESULTS: Least significant changes statistically differed over time for cardiac index, stroke volume index, pulse pressure variation and stroke volume variation (p \textless 0.001). Least significant changes ranged from 1.3 to 0.7% for cardiac index, from 1.3 to 0.8% for stroke volume index, from 10 to 4.9% for pulse pressure variation and from 10.8 to 4.3% for stroke volume variation. CONCLUSION: To conclude, the present study suggests that pulse contour analysis is able to detect rapid and small changes in cardiac index and stroke volume index, but the interpretation of rapid and small changes of pulse pressure variation and stroke volume variation must be done with caution.
dc.language.isoENen_US
dc.rightsAttribution 3.0 United States
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/us/
dc.subjectArticle CLINIQUE
dc.subject.enPrecision
dc.subject.enPulse contour
dc.subject.enPulse pressure variation
dc.subject.enStroke volume
dc.subject.enStroke volume variation
dc.title.enEvaluation of least significant changes of pulse contour analysis-derived parameters
dc.typeArticle de revueen_US
dc.identifier.doi10.1186/s13613-019-0590-zen_US
dc.subject.halSciences du Vivant [q-bio]/Médecine humaine et pathologieen_US
dc.identifier.pubmed31602550en_US
bordeaux.journalAnnals of intensive careen_US
bordeaux.page116en_US
bordeaux.volume9en_US
bordeaux.hal.laboratoriesBiologie des maladies cardiovasculaires - U1034en_US
bordeaux.issue1en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.institutionINSERM
bordeaux.teamBIOSTAT_BPH
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
hal.exportfalse
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Annals%20of%20intensive%20care&rft.date=2019-10&rft.volume=9&rft.issue=1&rft.spage=116&rft.epage=116&rft.eissn=2110-5820&rft.issn=2110-5820&rft.au=DE%20COURSON%20DE%20LA%20VILLENEUVE,%20Hugues&FERRER,%20Loic&CANE,%20Gregoire&VERCHERE,%20Eric&SESAY,%20Musa&rft.genre=article


Fichier(s) constituant ce document

Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée