Mostrar el registro sencillo del ítem
Improved Detection of Plasmon Waveguide Resonance Using Diverging Beam, Liquid Crystal Retarder, and Application to Lipid Orientation Determination
dc.rights.license | open | en_US |
dc.contributor.author | ISAACS, Sivan | |
hal.structure.identifier | Chimie et Biologie des Membranes et des Nanoobjets [CBMN] | |
dc.contributor.author | HARTE, Etienne | |
hal.structure.identifier | Chimie et Biologie des Membranes et des Nanoobjets [CBMN] | |
dc.contributor.author | ALVES, Isabel | |
dc.contributor.author | ABDULHALIM, Ibrahim | |
dc.date.accessioned | 2021-07-13T14:43:10Z | |
dc.date.available | 2021-07-13T14:43:10Z | |
dc.date.issued | 2019 | |
dc.identifier.issn | 1424-8220 | en_US |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/106541 | |
dc.description.abstractEn | Plasmon waveguide resonance (PWR) sensors exhibit narrow resonances at the two orthogonal polarizations, transverse electric (TE) and transverse magnetic (TM), which are narrower by almost an order of a magnitude than the standard surface plasmon resonance (SPR), and thus the figure of merit is enhanced. This fact is useful for measuring optical anisotropy of materials on the surface and determining the orientation of molecules with high resolution. Using the diverging beam approach and a liquid crystal retarder, we present experimental results by simultaneous detection of TE and TM polarized resonances as well as using fast higher contrast serial detection with a variable liquid crystal retarder. While simultaneous detection makes the system simpler, a serial one has the advantage of obtaining a larger contrast of the resonances and thus an improved signal-to-noise ratio. Although the sensitivity of the PWR resonances is smaller than the standard SPR, the angular width is much smaller, and thus the figure of merit is improved. When the measurement methodology has a high enough angular resolution, as is the one presented here, the PWR becomes advantageous over other SPR modes. The possibility of carrying out exact numerical simulations for anisotropic molecules using the 4 * 4 matrix approach brings another advantage of the PWR over SPR on the possibility of extracting the orientation of molecules adsorbed to the surface. High sensitivity of the TE and TM signals to the anisotropic molecules orientation is found here, and comparison to the experimental data allowed detection of the orientation of lipids on the sensor surface. The molecular orientations cannot be fully determined from the TM polarization alone as in standard SPR, which underlines the additional advantage of the PWR technique. | |
dc.language.iso | EN | en_US |
dc.rights | Attribution 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/us/ | * |
dc.subject.en | surface plasmon resonance | |
dc.subject.en | plasmon waveguide resonance | |
dc.subject.en | liquid crystal | |
dc.subject.en | biosensors | |
dc.title.en | Improved Detection of Plasmon Waveguide Resonance Using Diverging Beam, Liquid Crystal Retarder, and Application to Lipid Orientation Determination | |
dc.type | Article de revue | en_US |
dc.identifier.doi | 10.3390/s19061402 | en_US |
dc.subject.hal | Chimie/Matériaux | en_US |
bordeaux.journal | Sensors | en_US |
bordeaux.page | 12 p. | en_US |
bordeaux.volume | 19 | en_US |
bordeaux.hal.laboratories | Institut de Chimie & de Biologie des Membranes & des Nano-objets (CBMN) - UMR 5248 | en_US |
bordeaux.issue | 6 | en_US |
bordeaux.institution | Université de Bordeaux | en_US |
bordeaux.institution | Bordeaux INP | en_US |
bordeaux.institution | CNRS | en_US |
bordeaux.peerReviewed | oui | en_US |
bordeaux.inpress | non | en_US |
hal.identifier | hal-03082899 | |
hal.export | false | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Sensors&rft.date=2019&rft.volume=19&rft.issue=6&rft.spage=12%20p.&rft.epage=12%20p.&rft.eissn=1424-8220&rft.issn=1424-8220&rft.au=ISAACS,%20Sivan&HARTE,%20Etienne&ALVES,%20Isabel&ABDULHALIM,%20Ibrahim&rft.genre=article |