Afficher la notice abrégée

dc.contributor.advisorLewis, Noëlle
dc.contributor.advisorRenaud, Sylvie
dc.contributor.authorCASTELLI, Jonathan
dc.contributor.otherLewis, Noëlle
dc.contributor.otherRenaud, Sylvie
dc.contributor.otherBernard, Serge
dc.contributor.otherHistace, Aymeric
dc.contributor.otherJung, Ranu
dc.contributor.otherDubois, Rémi
dc.date2017-12-06
dc.identifier.urihttp://www.theses.fr/2017BORD0812/abes
dc.identifier.uri
dc.identifier.urihttps://tel.archives-ouvertes.fr/tel-01897367
dc.identifier.nnt2017BORD0812
dc.description.abstractLa bioélectronique est un domaine interdisciplinaire qui étudie les interconnexions et les interactions entre entités biologiques (cellules, tissus, organes) et systèmes électroniques,par l’intermédiaire du transducteur adéquat. Pour des cellules ou des tissus excitables (neurones, muscles, ...), le transducteur prend la forme d’une simple électrode, car ces tissus produisent une activité électrique spontanée ou, dans le sens inverse, peuvent être excités par un signal électrique externe. Cette communication bidirectionnelle donne lieu à deux schémas expérimentaux : l’acquisition et la stimulation. L’acquisition consiste à enregistrer, traiter et analyser les bio-signaux alors que la stimulation consiste à appliquer le courant électrique adéquat aux tissus vivants, pour déclencher une réaction. Cette thèse se concentre sur ce dernier point : deux générations de système de stimulation ont été développées, chacune basée sur un circuit intégré spécifique et adaptée à différents contextes applicatifs.Tout d’abord, le cadre scientifique a été celui du projet CENAVEX, axé sur la stimulation électrique fonctionnelle pour réhabiliter la fonction respiratoire, suite à une lésion de la moelle épinière. Ensuite, les objectifs de conception ont été étendus pour couvrir de nouveaux besoins d’application : la surveillance de l’impédance électrique in situ et l’exploration des formes d’onde de stimulation originales. Le premier pourrait être une solution pour suivre la réaction tissulaire après l’implantation d’une électrode, contribuant ainsi à la biocompatibilité à long terme des implants ; le second propose d’aller au-delà dela conventionnelle impulsion biphasique carrée et d’explorer de nouvelles formes d’ondes qui pourraient être plus efficaces en termes de consommation d’énergie, pour un effet physiologique donné.Le travail présenté dans ce manuscrit contribue à la conception, à la fabrication et au test de dispositifs de stimulation innovants. Cela a conduit au développement de deux circuits intégrés et de deux dispositifs de stimulation permettant une stimulation multicanal.Les caractérisations électriques et les validations biologiques, de la faisabilité in vitro aux expériences in vivo, ont été menées et sont décrites dans ce manuscrit.
dc.description.abstractEnBioelectronics is a cross-disciplinary field that studies interconnections and interactions between biological entities (cells, tissues, organs) and electronic systems, using the adequate transducer. For excitable cells or tissues (neurons, muscles, . . . ), the transducer takes the form of a simple electrode, as these tissues produce a spontaneous electrical activity or,in the opposite way, may be excited by an external electrical signal. This bi-directional communication gives rise to two experimental schemes: acquisition and stimulation. Acquisition consists in recording, processing and analyzing bio-signals whereas stimulation consists in applying the adequate electrical current to living tissues in order to trigger a reaction. This thesis focuses on the latter: two generations of stimulation systems have been developed, both being centered on an Application Specific Integrated Circuit, and adapted to different application contexts. First, the scientific framework was given by the CENAVEX project, focusing on Functional Electrical Stimulation to rehabilitate the respiratory function, following a Spinal Cord Injury. Then, the design objectives were extended to cover new application needs:in situ electrical impedance monitoring and exploration of original stimulation wave forms.The first one could be a solution to follow the tissue reaction after electrode implantation,hence contributing to long-term biocompatibility of implants; the second one proposes to go further the conventional constant biphasic pulse and explore new wave forms that couldbe most efficient in terms of energy consumption, for a given physiological effect.The work presented in this manuscript is a contribution to the design, fabrication and test of innovative stimulation devices. It leaded to the development of two integrated circuits and two stimulation devices permitting multichannel stimulation. Both electrical characterizations and biological validations, from in vitro feasibility to in vivo experiments, have been conducted and are described in this manuscript.
dc.language.isoen
dc.subjectMicro-électronique
dc.subjectFPGA
dc.subjectCircuits Intégrés
dc.subjectStimulation électrique fonctionelle
dc.subjectBioélectronique
dc.subjectSystème de stimulation
dc.subjectBoucle fermée
dc.subjectBoucle ouverte
dc.subject.enMicroelectronics
dc.subject.enFPGA
dc.subject.enIntegrated circuits
dc.subject.enAnalog IC design
dc.subject.enFunctional Electrical Stimulation
dc.subject.enBioelectronics
dc.subject.enStimulation device
dc.subject.enClosed-loop stimulation device
dc.subject.enOpen-loop stimulation device
dc.titleConception et validation de circuits intégrés et systèmes embarqués innovants pour applications de neurostimulation
dc.title.enDesign and validation of innovative integrated circuits and embedded systems for neurostimulation applications
dc.typeThèses de doctorat
dc.contributor.jurypresidentBernard, Serge
bordeaux.hal.laboratoriesLaboratoire de l'intégration du matériau au système (Talence, Gironde)
bordeaux.type.institutionBordeaux
bordeaux.thesis.disciplineElectronique
bordeaux.ecole.doctoraleÉcole doctorale des sciences physiques et de l’ingénieur (Talence, Gironde)
star.origin.linkhttps://www.theses.fr/2017BORD0812
dc.contributor.rapporteurBernard, Serge
dc.contributor.rapporteurHistace, Aymeric
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=Conception%20et%20validation%20de%20circuits%20int%C3%A9gr%C3%A9s%20et%20syst%C3%A8mes%20embarqu%C3%A9s%20innovants%20pour%20applications%20de%20neurostimulation&rft.atitle=Conception%20et%20validation%20de%20circuits%20int%C3%A9gr%C3%A9s%20et%20syst%C3%A8mes%20embarqu%C3%A9s%20innovants%20pour%20applications%20de%20neurostimulation&rft.au=CASTELLI,%20Jonathan&rft.genre=unknown


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée