Mostrar el registro sencillo del ítem

dc.rights.licenseopenen_US
hal.structure.identifierBiologie des maladies cardiovasculaires = Biology of Cardiovascular Diseases
dc.contributor.authorBIAIS, Matthieu
dc.contributor.authorSTECKEN, Laurent
dc.contributor.authorMARTIN, Aurélie
hal.structure.identifierBiologie des maladies cardiovasculaires = Biology of Cardiovascular Diseases
dc.contributor.authorROULLET, Stéphanie
dc.contributor.authorQUINART, Alice
hal.structure.identifierBiologie des maladies cardiovasculaires = Biology of Cardiovascular Diseases
dc.contributor.authorSZTARK, François
dc.date.accessioned2020
dc.date.available2020
dc.date.issued2017
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/20890
dc.description.abstractEnNon-invasive respiratory variations in arterial pulse pressure using infrared-plethysmography (PPVCNAP) are able to predict fluid responsiveness in mechanically ventilated patients. However, they cannot be continuously monitored. The present study evaluated a new algorithm allowing continuous measurements of PPVCNAP (PPVCNAPauto) (CNSystem, Graz, Austria). Thirty-five patients undergoing vascular surgery were studied after induction of general anaesthesia. Stroke volume was measured using the VigileoTM/FloTracTM. Invasive pulse pressure variations were manually calculated using an arterial line (PPVART) and PPVCNAPauto was continuously displayed. PPVART and PPVCNAPauto were simultaneously recorded before and after volume expansion (500 ml hydroxyethylstarch). Subjects were defined as responders if stroke volume increased by ≥15 %. Twenty-one patients were responders. Before volume expansion, PPVART and PPVCNAPauto exhibited a bias of 0.1 % and limits of agreement from -7.9 % to 7.9 %. After volume expansion, PPVART and PPVCNAPauto exhibited a bias of -0.4 % and limits of agreement from -5.3 % to 4.5 %. A 14 % baseline PPVART threshold discriminated responders with a sensitivity of 86 % (95 % CI 64-97 %) and a specificity of 100 % (95 % CI 77-100 %). Area under the receiver operating characteristic (ROC) curve for PPVART was 0.93 (95 % CI 0.79-0.99). A 15 % baseline PPVCNAPauto threshold discriminated responders with a sensitivity of 76% (95 % CI 53-92 %) and a specificity of 93 % (95 % CI 66-99 %). Area under the ROC curves for PPVCNAPauto was 0.91 (95 % CI 0.76-0.98), which was not different from that for PPVART. When compared with PPVART, PPVCNAPauto performs satisfactorily in assessing fluid responsiveness in hemodynamically stable surgical patients.
dc.language.isoENen_US
dc.subject*Article CLINIQUE
dc.subject.enCardiac output
dc.subject.eni.v. fluids
dc.subject.enMonitoring
dc.subject.enVascular surgery
dc.title.enAutomated, continuous and non-invasive assessment of pulse pressure variations using CNAP® system.
dc.typeArticle de revueen_US
dc.identifier.doi10.1007/s10877-016-9899-4en_US
dc.subject.halSciences du Vivant [q-bio]/Médecine humaine et pathologieen_US
bordeaux.journalJournal of Clinical Monitoring and Computingen_US
bordeaux.page685–692en_US
bordeaux.volume31en_US
bordeaux.hal.laboratoriesBiologie des maladies cardiovasculaires - U1034en_US
bordeaux.issue4en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
hal.exportfalse
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Journal%20of%20Clinical%20Monitoring%20and%20Computing&rft.date=2017&rft.volume=31&rft.issue=4&rft.spage=685%E2%80%93692&rft.epage=685%E2%80%93692&rft.au=BIAIS,%20Matthieu&STECKEN,%20Laurent&MARTIN,%20Aur%C3%A9lie&ROULLET,%20St%C3%A9phanie&QUINART,%20Alice&rft.genre=article


Archivos en el ítem

ArchivosTamañoFormatoVer

No hay archivos asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem