Mostrar el registro sencillo del ítem
La séquence 3D WMn MPRAGE améliore la détection des lésions médullaires dans la sclérose en plaques
dc.rights.license | authentification | en_US |
dc.contributor.advisor | DOUSSET, Vincent | |
dc.contributor.author | RAVACHE, Amaury | |
dc.date | 2022-09-29 | |
dc.date.accessioned | 2024-12-02T11:54:26Z | |
dc.date.available | 2024-12-02T11:54:26Z | |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/203658 | |
dc.description.abstract | Introduction : comparaison d’une séquence 3D WMn par rapport aux séquences conventionnelles 2D T2 FSE, 2D STIR, 2D PSIR et 3D T1-MPRAGE à 3T, afin de détecter des lésions de la moelle épinière dans la sclérose en plaques. Matériels et méthodes : il s’agit d’une étude prospective monocentrique qui a été approuvée par un comité d'examen institutionnel. Les patients ont été recrutés d'octobre 2021 à juillet 2022. La séquence 3D WMn et les séquences conventionnelles ont été examinées de manière aléatoire et indépendante par deux neuroradiologues. Pour toutes les lésions trouvées par les deux lecteurs, une session de lecture consensuelle a été réalisée par deux neuroradiologues seniors. Le critère d'évaluation principal était le nombre de lésions de la moelle épinière cervicale dans la SEP. Les critères d'évaluation secondaires comprenaient le nombre de lésions de la moelle épinière thoracique dans la SEP, le niveau précis des lésions, la confiance dans les lésions indiquées par les lecteurs, la concordance inter et intra-observateur, la présence d'artéfacts et la corrélation entre le nombre total de lésions et le score EDSS. Un test de Wilcoxon a été utilisé pour comparer les deux ensembles de données. Résultats 30 participants ont été inclus. La séquence 3D WMn a détecté significativement plus de lésions que l’ensemble des séquences conventionnelles (141 contre 83 respectivement, p<0.001). 23 participants avaient au moins une lésion sur la séquence 3D WMn qui n'était pas détectée sur les séquences conventionnelles. La confiance dans les lésions indiquées par les lecteurs était significativement plus élevée avec la séquence 3D WMn qu'avec les séquences conventionnelles. Les reproductibilités inter- et intra-observateurs étaient plus élevés avec la séquence 3D WMn. La séquence 3D WMn était sujette à très peu d'artefacts. Il n'y avait pas de corrélation avec le score EDSS. Conclusion : l'analyse a montré que la séquence 3D WMn améliorait la détection des lésions de la moelle épinière chez les patients atteints de SEP, avec une plus grande confiance dans leurs existences, une meilleure concordance inter et intra-lecteur, très peu d'artefacts, par rapport aux séquences conventionnelles. | |
dc.description.abstractEn | Abstract: background and purpose to compare 3D WMn with conventional dataset including 2D T2w, 2D STIR, 2D PSIR and 3D T1-MPRAGE at 3 Tesla in the detection of spinal cord injury in multiple sclerosis. Material and methods: this prospective single-center study was approved by an institutional review board and enrolled participants from October 2021 to July 2022. The two data sets were randomly and independently examined by 2 neuroradiologists. For all lesions found by the two readers, a consensus reading session was performed by two senior neuroradiologists. The primary endpoint was the number of cervical spinal cord lesions in MS. Secondary endpoint criteria included the number of thoracic spinal cord lesions in MS, precise level of lesions, rater-reported confidence in the lesions, inter- and intra-agreement, the presence of artifacts and the correlation between the number of total lesions with the EDSS score. A Wilcoxon’s test was used to compare the two datasets. Results: 30 participants were included. 3D WMn detected significantly more lesions than the conventional dataset (141 versus 83 respectively, p<0.001). 23 participants had at least one lesion on 3D WMn which was not detected on the conventional dataset. Rater-reported confidence were significantly higher with 3D WMn than with the conventional dataset. Inter- and intra-observer agreements were higher with 3D WMn. There were few artifacts on the 3D WMn. There was no correlation with the EDSS score. Conclusion: 3D WMn improved MS spinal cord lesion detection as compared to conventional dataset, with better confidence, and better inter and intra agreement with few artefacts. | |
dc.language.iso | FR | en_US |
dc.subject | Moelle épinière | |
dc.subject | IRM | |
dc.subject | Sclérose en plaques | |
dc.subject.en | Spinal cord | |
dc.subject.en | MRI | |
dc.subject.en | Multiple sclerosis | |
dc.title | La séquence 3D WMn MPRAGE améliore la détection des lésions médullaires dans la sclérose en plaques | |
dc.title.en | 3D WMn MPRAGE increased detection of spinal cord lesion in multiple sclerosis | |
dc.type | Thèse d'exercice | en_US |
dc.subject.hal | Sciences du Vivant [q-bio]/Médecine humaine et pathologie | en_US |
bordeaux.hal.laboratories | Thèses d’exercice de l’Université de Bordeaux | en_US |
bordeaux.type.institution | Université de Bordeaux | en_US |
bordeaux.thesis.type | thèse d'exercice de médecine spécialisée | en_US |
bordeaux.thesis.discipline | Radiologie | en_US |
hal.export | false | |
dc.rights.cc | Pas de Licence CC | en_US |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.title=La%20s%C3%A9quence%203D%20WMn%20MPRAGE%20am%C3%A9liore%20la%20d%C3%A9tection%20des%20l%C3%A9sions%20m%C3%A9dullaires%20dans%20la%20scl%C3%A9rose%20en%20plaques&rft.atitle=La%20s%C3%A9quence%203D%20WMn%20MPRAGE%20am%C3%A9liore%20la%20d%C3%A9tection%20des%20l%C3%A9sions%20m%C3%A9dullaires%20dans%20la%20scl%C3%A9rose%20en%20plaques&rft.au=RAVACHE,%20Amaury&rft.genre=unknown |