Afficher la notice abrégée

dc.rights.licenseopenen_US
dc.contributor.authorDEBORNE, Justine
dc.contributor.authorBENKHALED, Imad
IDREF: 235029815
hal.structure.identifierCentre de résonance magnétique des systèmes biologiques [CRMSB]
dc.contributor.authorBOUCHAUD, Véronique
dc.contributor.authorPINAUD, Noël
hal.structure.identifierISM Institut des Sciences Moléculaires
dc.contributor.authorCRÉMILLIEUX, Yannick
dc.date.accessioned2024-11-13T15:06:00Z
dc.date.available2024-11-13T15:06:00Z
dc.date.issued2024-02-24
dc.identifier.issn2045-2322en_US
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/203249
dc.description.abstractEnAbstract The evaluation of the efficacy of a drug is a fundamental step in the development of new treatments or in personalized therapeutic strategies and patient management. Ideally, this evaluation should be rapid, possibly in real time, easy to perform and reliable. In addition, it should be associated with as few adverse effects as possible for the patient. In this study, we present a device designed to meet these goals for assessing therapeutic response. This theranostic device is based on the use of magnetic resonance imaging and spectroscopy for the diagnostic aspect and on the application of the convection-enhanced delivery technique for the therapeutic aspect. The miniaturized device is implantable and can be used in vivo in a target tissue. In this study, the device was applied to rodent glioma models with local administration of choline kinase inhibitor and acquisition of magnetic resonance images and spectra at 7 Tesla. The variations in the concentration of key metabolites measured by the device during the administration of the molecules demonstrate the relevance of the approach and the potential of the device.
dc.language.isoENen_US
dc.rightsAttribution 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/us/*
dc.title.enImplantable theranostic device for in vivo real-time NMR evaluation of drug impact in brain tumors
dc.title.alternativeSci Repen_US
dc.typeArticle de revueen_US
dc.identifier.doi10.1038/s41598-024-55269-1en_US
dc.subject.halSciences du Vivant [q-bio]en_US
dc.identifier.pubmed38402370en_US
bordeaux.journalScientific Reportsen_US
bordeaux.page4541en_US
bordeaux.volume14en_US
bordeaux.hal.laboratoriesCentre de Résonance Magnétique des Systèmes Biologiques (CRMSB) - UMR 5536en_US
bordeaux.issue1en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.institutionCNRSen_US
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
bordeaux.import.sourcehal
hal.identifierhal-04731004
hal.version1
hal.popularnonen_US
hal.audienceInternationaleen_US
hal.exportfalse
workflow.import.sourcehal
dc.rights.ccPas de Licence CCen_US
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Scientific%20Reports&rft.date=2024-02-24&rft.volume=14&rft.issue=1&rft.spage=4541&rft.epage=4541&rft.eissn=2045-2322&rft.issn=2045-2322&rft.au=DEBORNE,%20Justine&BENKHALED,%20Imad&BOUCHAUD,%20V%C3%A9ronique&PINAUD,%20No%C3%ABl&CR%C3%89MILLIEUX,%20Yannick&rft.genre=article


Fichier(s) constituant ce document

Thumbnail
No Thumbnail [100%x80]

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée