Show simple item record

dc.rights.licenseopenen_US
hal.structure.identifierEnvironnements et Paléoenvironnements OCéaniques [EPOC]
hal.structure.identifierLaboratoire National de Métrologie et d'Essais (LNE), 1 rue Gaston Boissier, 75724 Paris, France
dc.contributor.authorBRIEUDES, Vincent
hal.structure.identifierLaboratoire National de Métrologie et d'Essais (LNE), 1 rue Gaston Boissier, 75724 Paris, France
dc.contributor.authorLARDY-FONTAN, S.
hal.structure.identifierLaboratoire National de Métrologie et d'Essais (LNE), 1 rue Gaston Boissier, 75724 Paris, France
dc.contributor.authorLALERE, B.
hal.structure.identifierLaboratoire National de Métrologie et d'Essais (LNE), 1 rue Gaston Boissier, 75724 Paris, France
dc.contributor.authorVASLIN-REIMANN, S.
hal.structure.identifierEnvironnements et Paléoenvironnements OCéaniques [EPOC]
dc.contributor.authorBUDZINSKI, Hélène
ORCID: 0000-0003-1028-9154
IDREF: 070478090
dc.date.accessioned2024-10-04T08:42:47Z
dc.date.available2024-10-04T08:42:47Z
dc.date.issued2016-01
dc.identifier.issn0039-9140en_US
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/202249
dc.description.abstractEnThe present work describes the development and validation of a reference method conducted at the French National Institute of Metrology (LNE) for the quantitative determination of psychoactive compounds in the dissolved fraction of surface waters. More specifically an isotope dilution-SPE-LC-MS/MS based method has been implemented for the characterization of a broad range of analytes belonging to different classes of psychotropic drugs such as benzodiazepines, antidepressants, stimulants, opiates and opioids, anticonvulsants, anti-dementia drugs, analgesics as well as the anti-inflammatory drug diclofenac in the low ng L(-1) range of concentration. Full validation of the method was performed following procedures described by the French standard NF T90-210. Limits of quantification between 0.14 and 3.54 ng L(-1) were obtained. Method recoveries from 71 to 123% were observed with standard deviation below 10% in intermediate precision conditions. Accuracy was determined for every compound: measurement errors were between -4 and +1% and standard deviations in intermediate precision conditions were included within a 1-9% interval. Finally, measurement uncertainties were evaluated following the Guide to the expression of uncertainty in measurement (GUM). Expanded uncertainties (k=2) ranged from 2% for carbamazepine, EDDP (2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine) and venlafaxine to 17% for diazepam. The validated method was implemented to Seine river surface waters demonstrating its fitness for purpose. All compounds were detected and 22 out of 25 analytes were quantified. More specifically, measured concentration ranged from 0.39 ng L(-1) for MDMA (3,4-methylene-dioxy-N-methylamphetamine) to 182 ng L(-1) for gabapentine.
dc.language.isoENen_US
dc.subject.enIllicit drugs
dc.subject.enIsotope dilution
dc.subject.enMethod validation
dc.subject.enMetrology
dc.subject.enPharmaceuticals
dc.subject.enSurface waters
dc.subject.enUncertainties.
dc.title.enValidation and uncertainties evaluation of an isotope dilution-SPE-LC–MS/MS for the quantification of drug residues in surface waters
dc.typeArticle de revueen_US
dc.identifier.doi10.1016/j.talanta.2015.06.073en_US
dc.subject.halSciences de l'environnementen_US
dc.subject.halChimieen_US
bordeaux.journalTalantaen_US
bordeaux.page138-147en_US
bordeaux.volume146en_US
bordeaux.hal.laboratoriesEPOC : Environnements et Paléoenvironnements Océaniques et Continentaux - UMR 5805en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.institutionCNRSen_US
bordeaux.teamLPTCen_US
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
bordeaux.import.sourcehal
hal.identifierhal-03159519
hal.version1
hal.popularnonen_US
hal.audienceInternationaleen_US
hal.exportfalse
workflow.import.sourcehal
dc.rights.ccPas de Licence CCen_US
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Talanta&rft.date=2016-01&rft.volume=146&rft.spage=138-147&rft.epage=138-147&rft.eissn=0039-9140&rft.issn=0039-9140&rft.au=BRIEUDES,%20Vincent&LARDY-FONTAN,%20S.&LALERE,%20B.&VASLIN-REIMANN,%20S.&BUDZINSKI,%20H%C3%A9l%C3%A8ne&rft.genre=article


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record