Sensitivity of the Electrocardiography Inverse Solution to the Torso Conductivity Uncertainties
hal.structure.identifier | IHU-LIRYC | |
hal.structure.identifier | Modélisation et calculs pour l'électrophysiologie cardiaque [CARMEN] | |
dc.contributor.author | ZEMZEMI, Nejib | |
hal.structure.identifier | Laboratoire d'Etudes et Recherche en Mathématiques Appliquées [LERMA] | |
dc.contributor.author | ABOULAICH, Rajae | |
hal.structure.identifier | Laboratoire d'Etudes et Recherche en Mathématiques Appliquées [LERMA] | |
dc.contributor.author | FIKAL, Najib | |
hal.structure.identifier | Laboratoire d'Etudes et Recherche en Mathématiques Appliquées [LERMA] | |
dc.contributor.author | EL GUARMAH, Emahdi | |
dc.contributor.editor | Hans van Assen; Peter Bovendeerd ; Tammo Delhaas | |
dc.date.accessioned | 2024-04-04T03:17:05Z | |
dc.date.available | 2024-04-04T03:17:05Z | |
dc.date.issued | 2015 | |
dc.identifier.isbn | 978-3-319-20308-9 | |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/194277 | |
dc.description.abstractEn | Electrocardiography imaging (ECGI) is a new non invasive technology used for heart diagnosis. It allows to construct the electrical potential on the heart surface only from measurement on the body surface and some geometrical informations of the torso. The purpose of this work is twofold: First, we propose a new formulation to calculate the distribution of the electric potential on the heart, from measurements on the torso surface. Second, we study the influence of the errors and uncertainties on the conductivity parameters, on the ECGI solution. We use an optimal control formulation for the mathematical formulation of the problem with a stochastic diffusion equation as a constraint. The descretization is done using stochastic Galerkin method allowing to separate random and de-terministic variables. The optimal control problem is solved using a conjugate gradient method where the gradient of the cost function is computed with an ad-joint technique. The efficiency of this approach to solve the inverse problem and the usability to quantify the effect of conductivity uncertainties in the torso are demonstrated through a number of numerical simulations on a 2D geometrical model. Our results show that adding ±50% uncertainties in the fat conductivity does not alter the inverse solution, whereas adding ±50% uncertainties in the lung conductivity affects the reconstructed heart potential by almost 50%. | |
dc.language.iso | en | |
dc.publisher | Springer | |
dc.source.title | Functional Imaging and Modeling of the Heart | |
dc.subject.en | Inverse problem | |
dc.subject.en | Electrocardiography Imaging | |
dc.subject.en | Stochastic Differential Equation | |
dc.title.en | Sensitivity of the Electrocardiography Inverse Solution to the Torso Conductivity Uncertainties | |
dc.type | Chapitre d'ouvrage | |
dc.identifier.doi | 10.1007/978-3-319-20309-6_54 | |
dc.subject.hal | Informatique [cs]/Modélisation et simulation | |
dc.subject.hal | Mathématiques [math]/Optimisation et contrôle [math.OC] | |
dc.subject.hal | Mathématiques [math]/Equations aux dérivées partielles [math.AP] | |
bordeaux.page | 475-483 | |
bordeaux.volume | Lecture Notes in Computer Science | |
bordeaux.hal.laboratories | Institut de Mathématiques de Bordeaux (IMB) - UMR 5251 | * |
bordeaux.issue | 9126 | |
bordeaux.institution | Université de Bordeaux | |
bordeaux.institution | Bordeaux INP | |
bordeaux.institution | CNRS | |
bordeaux.title.proceeding | Functional Imaging and Modeling of the Heart | |
hal.identifier | hal-01222381 | |
hal.version | 1 | |
hal.popular | non | |
hal.audience | Internationale | |
hal.origin.link | https://hal.archives-ouvertes.fr//hal-01222381v1 | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.btitle=Functional%20Imaging%20and%20Modeling%20of%20the%20Heart&rft.date=2015&rft.volume=Lecture%20Notes%20in%20Computer%20Science&rft.issue=9126&rft.spage=475-483&rft.epage=475-483&rft.au=ZEMZEMI,%20Nejib&ABOULAICH,%20Rajae&FIKAL,%20Najib&EL%20GUARMAH,%20Emahdi&rft.isbn=978-3-319-20308-9&rft.genre=unknown |
Fichier(s) constituant ce document
Fichiers | Taille | Format | Vue |
---|---|---|---|
Il n'y a pas de fichiers associés à ce document. |