Mostrar el registro sencillo del ítem
Online real-time reconstruction of adaptive TSENSE with commodity CPU / GPU hardware
hal.structure.identifier | Imagerie moléculaire et fonctionnelle: de la physiologie à la thérapie | |
dc.contributor.author | ROUJOL, Sébastien | |
hal.structure.identifier | Institut de Mathématiques de Bordeaux [IMB] | |
dc.contributor.author | DENIS DE SENNEVILLE, Baudouin | |
dc.contributor.author | VAHALLA, Erkki | |
hal.structure.identifier | Aarhus University [Aarhus] | |
dc.contributor.author | SANGILD SORENSEN, Thomas | |
hal.structure.identifier | University Medical Center [Utrecht] [UMCU] | |
dc.contributor.author | MOONEN, Chrit | |
hal.structure.identifier | University Medical Center [Utrecht] [UMCU] | |
dc.contributor.author | RIES, Mario | |
dc.date.accessioned | 2024-04-04T03:10:21Z | |
dc.date.available | 2024-04-04T03:10:21Z | |
dc.date.issued | 2010-06-01 | |
dc.identifier.issn | 0740-3194 | |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/193683 | |
dc.description.abstractEn | Adaptive TSENSE has been suggested as a robust parallel imaging method suitable for MR-guidance of interventional procedures. However, in practice, the reconstruction of adaptive TSENSE images obtained with large coil arrays leads to long reconstruction times and latencies and thus hampers its use for applications such as MR-guided thermotherapy or cardiovascular catheterization.Here, we demonstrate a real-time reconstruction pipeline for adaptive TSENSE with low image latencies and high frame-rates on affordable commodity PC hardware. For typical image sizes used in interventional imaging (128×96, 16-channels, SENSE-factor 2-4), the pipeline is able to reconstruct adaptive TSENSE images with image latencies below 90 ms at frame-rates of up to 40 images/s, rendering the MR-performance in practice limited by the constraints of the MR-acquisition. Its performance is demonstrated by the online reconstruction of in-vivo MR images for rapid temperature mapping of the kidney and for cardiac cathetirization. | |
dc.language.iso | en | |
dc.publisher | Wiley | |
dc.title.en | Online real-time reconstruction of adaptive TSENSE with commodity CPU / GPU hardware | |
dc.type | Article de revue | |
dc.subject.hal | Sciences de l'ingénieur [physics]/Traitement du signal et de l'image | |
bordeaux.journal | Magnetic Resonance in Medicine | |
bordeaux.hal.laboratories | Institut de Mathématiques de Bordeaux (IMB) - UMR 5251 | * |
bordeaux.institution | Université de Bordeaux | |
bordeaux.institution | Bordeaux INP | |
bordeaux.institution | CNRS | |
bordeaux.peerReviewed | oui | |
hal.identifier | hal-01504334 | |
hal.version | 1 | |
hal.popular | non | |
hal.audience | Internationale | |
hal.origin.link | https://hal.archives-ouvertes.fr//hal-01504334v1 | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Magnetic%20Resonance%20in%20Medicine&rft.date=2010-06-01&rft.eissn=0740-3194&rft.issn=0740-3194&rft.au=ROUJOL,%20S%C3%A9bastien&DENIS%20DE%20SENNEVILLE,%20Baudouin&VAHALLA,%20Erkki&SANGILD%20SORENSEN,%20Thomas&MOONEN,%20Chrit&rft.genre=article |
Archivos en el ítem
Archivos | Tamaño | Formato | Ver |
---|---|---|---|
No hay archivos asociados a este ítem. |