Mostrar el registro sencillo del ítem
Evaluating the benefit of PBS vs. VMAT dose distributions in terms of dosimetric sparing and robustness against inter-fraction anatomical changes for pediatric abdominal tumors
hal.structure.identifier | University Medical Center [Utrecht] [UMCU] | |
dc.contributor.author | GUERREIRO, Filipa | |
hal.structure.identifier | University Medical Center [Utrecht] [UMCU] | |
dc.contributor.author | ZACHIU, Cornel | |
hal.structure.identifier | University Medical Center [Utrecht] [UMCU] | |
dc.contributor.author | SERAVALLI, Enrica | |
hal.structure.identifier | University Medical Center Groningen [Groningen] [UMCG] | |
dc.contributor.author | CASSIA ORABONI, Ribeiro | |
hal.structure.identifier | University Medical Center [Utrecht] [UMCU] | |
dc.contributor.author | JANSSENS, Geert | |
hal.structure.identifier | University Medical Center [Utrecht] [UMCU] | |
dc.contributor.author | RIES, Mario | |
hal.structure.identifier | Modélisation Mathématique pour l'Oncologie [MONC] | |
hal.structure.identifier | Institut de Mathématiques de Bordeaux [IMB] | |
dc.contributor.author | DENIS DE SENNEVILLE, Baudouin | |
hal.structure.identifier | University Medical Center Groningen [Groningen] [UMCG] | |
dc.contributor.author | MADURO, John | |
hal.structure.identifier | University Medical Center Groningen [Groningen] [UMCG] | |
dc.contributor.author | BROUWER, Charlotte | |
hal.structure.identifier | University Medical Center Groningen [Groningen] [UMCG] | |
dc.contributor.author | KOREVAAR, Erik | |
hal.structure.identifier | University Medical Center Groningen [Groningen] [UMCG] | |
dc.contributor.author | KNOPF, Antje | |
hal.structure.identifier | University Medical Center [Utrecht] [UMCU] | |
dc.contributor.author | RAAYMAKERS, Bas | |
dc.date.accessioned | 2024-04-04T02:58:42Z | |
dc.date.available | 2024-04-04T02:58:42Z | |
dc.date.issued | 2019-09-01 | |
dc.identifier.issn | 0167-8140 | |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/192679 | |
dc.description.abstractEn | BACKGROUND AND PURPOSE:To evaluate the dosimetric sparing and robustness against inter-fraction anatomical changes between photon and proton dose distributions for children with abdominal tumors.MATERIAL AND METHODS:Volumetric modulated arc therapy (VMAT) and intensity-modulated pencil beam scanning (PBS) proton dose distributions were calculated for 20 abdominal pediatric cases (average 3, range 1-8 years). VMAT plans were based on a full-arc while PBS plans on 2-3 posterior-oblique irradiation fields. Plans were robustly optimized on a patient-specific internal target volume (ITV) using a uniform 5 mm set-up uncertainty. Additionally, for the PBS plans a ± 3% proton range uncertainty was accounted for. Fractional dose re-calculations were performed using the planning computed tomography (CT) deformably registered to the daily cone-beam CT (CBCT) images. Fractional doses were accumulated rigidly. Planned and CBCT accumulated VMAT and PBS dose distributions were compared using dose-volume histogram (DVH) parameters.RESULTS:Significant better sparing of the organs at risk with a maximum reduction in the mean dose of 40% was achieved with PBS. Mean ITV DVH parameters differences between planned and CBCT accumulated dose distributions were smaller than 0.5% for both VMAT and PBS. However, the ITV coverage (V95% > 99%) was not reached for one patient for the accumulated VMAT dose distribution.CONCLUSIONS:For pediatric patients with abdominal tumors, improved dosimetric sparing was obtained with PBS compared to VMAT. In addition, PBS delivered by posterior-oblique irradiation fields demonstrated to be robust against anatomical inter-fraction changes. Compared to PBS, daily anatomical changes proved to affect the target coverage of VMAT dose distributions to a higher extent. | |
dc.language.iso | en | |
dc.publisher | Elsevier | |
dc.subject.en | VMAT | |
dc.subject.en | Re-planning | |
dc.subject.en | Inter-fraction uncertainties | |
dc.subject.en | Children abdominal tumors | |
dc.subject.en | Robust pencil beam scanning | |
dc.subject.en | Pediatric IGRT | |
dc.subject.en | Proton therapy | |
dc.title.en | Evaluating the benefit of PBS vs. VMAT dose distributions in terms of dosimetric sparing and robustness against inter-fraction anatomical changes for pediatric abdominal tumors | |
dc.type | Article de revue | |
dc.identifier.doi | 10.1016/j.radonc.2019.06.025 | |
dc.subject.hal | Sciences de l'ingénieur [physics]/Traitement du signal et de l'image | |
bordeaux.journal | Radiotherapy & Oncology | |
bordeaux.hal.laboratories | Institut de Mathématiques de Bordeaux (IMB) - UMR 5251 | * |
bordeaux.institution | Université de Bordeaux | |
bordeaux.institution | Bordeaux INP | |
bordeaux.institution | CNRS | |
bordeaux.peerReviewed | oui | |
hal.identifier | hal-02387725 | |
hal.version | 1 | |
hal.popular | non | |
hal.audience | Internationale | |
hal.origin.link | https://hal.archives-ouvertes.fr//hal-02387725v1 | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Radiotherapy%20&%20Oncology&rft.date=2019-09-01&rft.eissn=0167-8140&rft.issn=0167-8140&rft.au=GUERREIRO,%20Filipa&ZACHIU,%20Cornel&SERAVALLI,%20Enrica&CASSIA%20ORABONI,%20Ribeiro&JANSSENS,%20Geert&rft.genre=article |
Archivos en el ítem
Archivos | Tamaño | Formato | Ver |
---|---|---|---|
No hay archivos asociados a este ítem. |