Afficher la notice abrégée

hal.structure.identifierUnité de Mathématiques Pures et Appliquées [UMPA-ENSL]
dc.contributor.authorENAULT, S.
hal.structure.identifierInstitut de Mathématiques de Bordeaux [IMB]
dc.contributor.authorLOMBARDI, D.
hal.structure.identifierInstitut National des Sciences Appliquées - Toulouse [INSA Toulouse]
dc.contributor.authorPONCET, Philippe
hal.structure.identifierLaboratoire Jacques-Louis Lions [LJLL]
hal.structure.identifierNumerical simulation of biological flows [REO]
dc.contributor.authorTHIRIET, Marc
dc.date.accessioned2024-04-04T02:49:02Z
dc.date.available2024-04-04T02:49:02Z
dc.date.issued2010
dc.identifier.issn1270-900X
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/191789
dc.description.abstractCe travail présente une étude numérique des interactions élémentaires entre le mucus de l'appareil respiratoire, la circulation de l'air et le mouvement vibratoire des cellules épithéliales ciliées tapissant la membrane pulmonaire. On s'intéresse en particulier à l'identification des paramètres les plus importants parmi les données rhéologiques, le dimensionnement physiologique et la configuration numérique. Ces résultats préliminaires sont cruciaux afin d'envisager l'étude de cas plus généraux de transport du mucus respiratoire. Un tel outil numérique aura pour but de quantifier la mobilité du mucus et sa capacité à expulser les pathogènes ou à délivrer un aérosol à travers membrane. La diffusion a été identifiée comme étant le phénomène dominant, comme attendu à l'échelle du micromètre, et son opérateur de diffusion associé a été observé comme étant extrêmement raide. D'autre part, il a été montré que la vibration de l'épithélium est bien plus efficace que la circulation de l'air pour assurer le transport du mucus.
dc.description.abstractEnThis study presents a numerical investigation of basic interactions between respiratory mucus motion, air circulation and epithelium ciliated cells vibration. One focuses on identification of meaningful rheological parameters, physiological and numerical simulation dimensioning. These preliminary results are crucial before the study of more general configurations of respiratory mucus motion. The numerical study presented in this work aims at providing a first numerical tool able to simulate the effects of mucus mobility and its ability to carry out pathogens or to deliver aerosol therapy to membrane wall cells. Momentum diffusion is identified as the dominant effect, as expected in this micrometer scale configuration, and its associate momentum diffusion operator is shown to be extremely stiff. Furthermore, epithelium vibration is shown to be much more efficient than air circulation for mucus propulsion.
dc.language.isoen
dc.publisherEDP Sciences
dc.title.enMucus dynamics subject to air and wall motion
dc.typeArticle de revue
dc.subject.halPhysique [physics]/Mécanique [physics]/Biomécanique [physics.med-ph]
dc.subject.halSciences de l'ingénieur [physics]/Mécanique [physics.med-ph]/Biomécanique [physics.med-ph]
dc.subject.halMathématiques [math]/Analyse numérique [math.NA]
bordeaux.journalESAIM: Proceedings
bordeaux.page125-141
bordeaux.volume30
bordeaux.hal.laboratoriesInstitut de Mathématiques de Bordeaux (IMB) - UMR 5251*
bordeaux.institutionUniversité de Bordeaux
bordeaux.institutionBordeaux INP
bordeaux.institutionCNRS
bordeaux.peerReviewedoui
hal.identifierinria-00543082
hal.version1
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//inria-00543082v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=ESAIM:%20Proceedings&rft.date=2010&rft.volume=30&rft.spage=125-141&rft.epage=125-141&rft.eissn=1270-900X&rft.issn=1270-900X&rft.au=ENAULT,%20S.&LOMBARDI,%20D.&PONCET,%20Philippe&THIRIET,%20Marc&rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée