Mostrar el registro sencillo del ítem

dc.rights.licenseopenen_US
dc.contributor.authorASCIONE, Ciro
dc.contributor.authorKOWALEWSKI, Christopher
dc.contributor.authorBERGONTI, Marco
dc.contributor.authorYOKOYAMA, Masaaki
dc.contributor.authorMONACO, Cinzia
hal.structure.identifierBordeaux population health [BPH]
dc.contributor.authorBOUYER, Benjamin
dc.contributor.authorCHAUVEL, Rémi
dc.contributor.authorARNAUD, Marine
dc.contributor.authorBULIARD, Samuel
dc.contributor.authorTIXIER, Romain
dc.contributor.authorVLACHOS, Konstantinos
dc.contributor.authorKRISAI, Philipp
dc.contributor.authorKAMAKURA, Tsukasa
dc.contributor.authorTAKAGI, Takamitsu
dc.contributor.authorDUCHATEAU, Josselin
dc.contributor.authorPAMBRUN, Thomas
dc.contributor.authorDERVAL, Nicolas
dc.contributor.authorHOCINI, Mélèze
dc.contributor.authorHAÏSSAGUERRE, Michel
dc.contributor.authorJAÏS, Pierre
dc.contributor.authorSACHER, Frederic
dc.date.accessioned2023-10-17T09:17:28Z
dc.date.available2023-10-17T09:17:28Z
dc.date.issued2023-10-01
dc.identifier.issn1556-3871en_US
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/184447
dc.description.abstractEnOmnipolar technology (OT) was recently proposed to generate electroanatomic voltage maps with orientation-independent electrograms. We describe the first cohort of patients undergoing ventricular tachycardia (VT) ablation guided by OT. The purpose of this study was to compare omnipolar and bipolar high-density maps with regard to voltage amplitude, late potential (LP) annotation, and isochronal late activation mapping distribution. A total of 24 patients (16 [66%] ischemic cardiomyopathy and 12 [50%] redo cases) underwent VT ablation under OT guidance. Twenty-seven sinus rhythm substrate maps and 10 VT activation maps were analyzed. Omnipolar and bipolar (HD Wave Solution algorithm, Abbott, Abbott Park, IL) voltages were compared. Areas of LPs were correlated with the VT isthmus areas, and late electrogram misannotation was evaluated. Deceleration zones based on isochronal late activation maps were analyzed by 2 blinded operators and compared to the VT isthmuses. OT maps had higher point density (13.8 points/cm vs 8.0 points/cm). Omnipolar points had 7.1% higher voltages than bipolar points within areas of dense scar and border zone. The number of misannotated points was significantly lower for OT maps (6.8% vs 21.9%; P = .01), showing comparable sensitivity (53% vs 59%) but higher specificity (79% vs 63%). The sensitivity and specificity of detection of the VT isthmus in the deceleration zones were, respectively, 75% and 65% for OT and 35% and 55% for bipolar mapping. At 8.4 months, 71% freedom from VT recurrence was achieved. OT is a valuable tool for guiding VT ablation, providing more accurate identification of LPs and isochronal crowding due to slightly higher voltages.
dc.language.isoENen_US
dc.subject.enBipolar
dc.subject.enCatheter ablation
dc.subject.enElectrograms
dc.subject.enMapping
dc.subject.enOmnipolar
dc.subject.enVentricular tachycardia
dc.title.enOmnipolar versus bipolar mapping to guide ventricular tachycardia ablation
dc.title.alternativeHeart Rhythmen_US
dc.typeArticle de revueen_US
dc.identifier.doi10.1016/j.hrthm.2023.06.022en_US
dc.subject.halSciences du Vivant [q-bio]/Santé publique et épidémiologieen_US
dc.identifier.pubmed37414109en_US
bordeaux.journalHeart Rhythmen_US
bordeaux.page1370-1377en_US
bordeaux.volume20en_US
bordeaux.hal.laboratoriesBordeaux Population Health Research Center (BPH) - UMR 1219en_US
bordeaux.issue10en_US
bordeaux.institutionUniversité de Bordeauxen_US
bordeaux.institutionINSERMen_US
bordeaux.teamAHEADen_US
bordeaux.peerReviewedouien_US
bordeaux.inpressnonen_US
bordeaux.import.sourcepubmed
hal.identifierhal-04245694
hal.version1
hal.date.transferred2023-10-17T09:17:30Z
hal.popularnonen_US
hal.audienceInternationaleen_US
hal.exporttrue
workflow.import.sourcepubmed
dc.rights.ccPas de Licence CCen_US
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Heart%20Rhythm&rft.date=2023-10-01&rft.volume=20&rft.issue=10&rft.spage=1370-1377&rft.epage=1370-1377&rft.eissn=1556-3871&rft.issn=1556-3871&rft.au=ASCIONE,%20Ciro&KOWALEWSKI,%20Christopher&BERGONTI,%20Marco&YOKOYAMA,%20Masaaki&MONACO,%20Cinzia&rft.genre=article


Archivos en el ítem

ArchivosTamañoFormatoVer

No hay archivos asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem