Transient Operation of a Four-Leg Inverter for Autonomous Applications With Unbalanced Load
dc.rights.license | open | en_US |
hal.structure.identifier | ESTIA INSTITUTE OF TECHNOLOGY | |
dc.contributor.author | VECHIU, Ionel
ORCID: 0000-0003-4108-3546 IDREF: 102417741 | |
hal.structure.identifier | ESTIA INSTITUTE OF TECHNOLOGY | |
dc.contributor.author | CUREA, Octavian
ORCID: 0000-0002-5030-2088 IDREF: 68259131 | |
hal.structure.identifier | ESTIA INSTITUTE OF TECHNOLOGY | |
dc.contributor.author | CAMBLONG, Haritza | |
dc.date.accessioned | 2023-08-25T12:55:29Z | |
dc.date.available | 2023-08-25T12:55:29Z | |
dc.date.issued | 2010-02-17 | |
dc.identifier.issn | 0885-8993 | en_US |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/183521 | |
dc.description.abstractEn | In this paper, the transient operation of a four-leg inverter equipped with an innovative control strategy under unbalanced load conditions is investigated. The inverter is proposed for transformerless hybrid power system applications, in order to provide simultaneous supply of three-phase and single-phase AC loads with balanced voltage and constant frequency. The four-leg inverter is controlled to ensure balanced voltage by means of a control strategy based on the decomposition of the supply three-phase voltage and current into instantaneous positive, negative, and homopolar sequence components using phasor representation. These three sequences are controlled independently in their own reference frames as DC signals. The implementation derived for the controller design is also described. The transient operation performance of the proposed control strategy has been tested in simulations with an average model and experimentally using a laboratory prototype. | |
dc.language.iso | EN | en_US |
dc.subject.en | Current control | |
dc.subject.en | DC-AC power conversion | |
dc.subject.en | Inverters | |
dc.subject.en | Hybrid power integration | |
dc.subject.en | Power quality | |
dc.subject.en | Symmetrical Components | |
dc.subject.en | Unbalance | |
dc.subject.en | Voltage control | |
dc.title.en | Transient Operation of a Four-Leg Inverter for Autonomous Applications With Unbalanced Load | |
dc.type | Article de revue | en_US |
dc.identifier.doi | 10.1109/TPEL.2009.2025275 | en_US |
dc.subject.hal | Sciences de l'ingénieur [physics]/Energie électrique | en_US |
bordeaux.journal | IEEE Transactions on Power Electronics | en_US |
bordeaux.page | 1591 - 1596 | en_US |
bordeaux.volume | 25 | en_US |
bordeaux.hal.laboratories | ESTIA - Recherche | en_US |
bordeaux.issue | 2 | en_US |
bordeaux.institution | Université de Bordeaux | en_US |
bordeaux.institution | Bordeaux INP | en_US |
bordeaux.institution | Bordeaux Sciences Agro | en_US |
bordeaux.peerReviewed | oui | en_US |
bordeaux.inpress | non | en_US |
bordeaux.import.source | hal | |
hal.identifier | hal-00547071 | |
hal.version | 1 | |
hal.popular | non | en_US |
hal.audience | Internationale | en_US |
hal.export | false | |
workflow.import.source | hal | |
dc.rights.cc | Pas de Licence CC | en_US |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=IEEE%20Transactions%20on%20Power%20Electronics&rft.date=2010-02-17&rft.volume=25&rft.issue=2&rft.spage=1591%20-%201596&rft.epage=1591%20-%201596&rft.eissn=0885-8993&rft.issn=0885-8993&rft.au=VECHIU,%20Ionel&CUREA,%20Octavian&CAMBLONG,%20Haritza&rft.genre=article |
Fichier(s) constituant ce document
Fichiers | Taille | Format | Vue |
---|---|---|---|
Il n'y a pas de fichiers associés à ce document. |