Mostrar el registro sencillo del ítem
High Stability Comparison of Atomic Fountains using two Different Cryogenic Oscillators
hal.structure.identifier | Systèmes de Référence Temps Espace [SYRTE] | |
dc.contributor.author | ABGRALL, Michel | |
hal.structure.identifier | Systèmes de Référence Temps Espace [SYRTE] | |
dc.contributor.author | GUÉNA, Jocelyne | |
hal.structure.identifier | Systèmes de Référence Temps Espace [SYRTE] | |
dc.contributor.author | LOURS, Michel | |
hal.structure.identifier | Systèmes de Référence Temps Espace [SYRTE] | |
hal.structure.identifier | Laboratoire Photonique, Numérique et Nanosciences [LP2N] | |
dc.contributor.author | SANTARELLI, Giorgio | |
hal.structure.identifier | The University of Western Australia [UWA] | |
dc.contributor.author | TOBAR, E | |
hal.structure.identifier | Systèmes de Référence Temps Espace [SYRTE] | |
dc.contributor.author | BIZE, Sébastien | |
hal.structure.identifier | Franche-Comté Électronique Mécanique, Thermique et Optique - Sciences et Technologies (UMR 6174) [FEMTO-ST] | |
dc.contributor.author | GROP, Serge | |
hal.structure.identifier | Franche-Comté Électronique Mécanique, Thermique et Optique - Sciences et Technologies (UMR 6174) [FEMTO-ST] | |
dc.contributor.author | DUBOIS, Benoît | |
hal.structure.identifier | Franche-Comté Électronique Mécanique, Thermique et Optique - Sciences et Technologies (UMR 6174) [FEMTO-ST] | |
dc.contributor.author | FLUHR, Christophe | |
hal.structure.identifier | Franche-Comté Électronique Mécanique, Thermique et Optique - Sciences et Technologies (UMR 6174) [FEMTO-ST] | |
dc.contributor.author | GIORDANO, Vincent | |
dc.date.accessioned | 2023-05-12T10:32:54Z | |
dc.date.available | 2023-05-12T10:32:54Z | |
dc.date.issued | 2016 | |
dc.identifier.issn | 0885-3010 | |
dc.identifier.uri | https://oskar-bordeaux.fr/handle/20.500.12278/181447 | |
dc.description.abstractEn | We present a detailed characterization of two atomic clock interrogation systems based on two different cryogenic sapphire oscillators operated simultaneously. We use them as references for two accurate fountain clock frequency standards participating in international atomic time and operating both at the quantum projection noise frequency limit. The two fountain comparison down to a few 10-16 over 28 days demonstrates the potential of a cryocooled oscillator to replace a He refilled cryogenic oscillator. | |
dc.language.iso | en | |
dc.publisher | Institute of Electrical and Electronics Engineers | |
dc.title.en | High Stability Comparison of Atomic Fountains using two Different Cryogenic Oscillators | |
dc.type | Article de revue | |
dc.identifier.doi | 10.1109/TUFFC.2016.2570898 | |
dc.subject.hal | Physique [physics]/Physique [physics]/Instrumentations et Détecteurs [physics.ins-det] | |
bordeaux.journal | IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control | |
bordeaux.page | 1198 - 1203 | |
bordeaux.volume | 63 | |
bordeaux.hal.laboratories | Laboratoire Photonique, Numérique et Nanosciences (LP2N) - UMR 5298 | * |
bordeaux.issue | 8 | |
bordeaux.institution | Université de Bordeaux | |
bordeaux.institution | CNRS | |
bordeaux.peerReviewed | oui | |
hal.identifier | hal-02300393 | |
hal.version | 1 | |
hal.origin.link | https://hal.archives-ouvertes.fr//hal-02300393v1 | |
bordeaux.COinS | ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=IEEE%20Transactions%20on%20Ultrasonics,%20Ferroelectrics%20and%20Frequency%20Control&rft.date=2016&rft.volume=63&rft.issue=8&rft.spage=1198%20-%201203&rft.epage=1198%20-%201203&rft.eissn=0885-3010&rft.issn=0885-3010&rft.au=ABGRALL,%20Michel&GU%C3%89NA,%20Jocelyne&LOURS,%20Michel&SANTARELLI,%20Giorgio&TOBAR,%20E&rft.genre=article |
Archivos en el ítem
Archivos | Tamaño | Formato | Ver |
---|---|---|---|
No hay archivos asociados a este ítem. |