Mostrar el registro sencillo del ítem

hal.structure.identifierLaboratoire de Physique des Lasers [LPL]
dc.contributor.authorCHANTEAU, Bruno
hal.structure.identifierMMTF
dc.contributor.authorLOPEZ, Olivier
hal.structure.identifierLaboratoire national de métrologie et d'essais - Systèmes de Référence Temps-Espace [LNE - SYRTE]
dc.contributor.authorZHANG, Wei
hal.structure.identifierLaboratoire national de métrologie et d'essais - Systèmes de Référence Temps-Espace [LNE - SYRTE]
dc.contributor.authorNICOLODI, Daniele
hal.structure.identifierSystèmes de Référence Temps Espace [SYRTE]
dc.contributor.authorARGENCE, Bérengère
hal.structure.identifierLaboratoire de Physique des Lasers [LPL]
dc.contributor.authorAUGUSTE, Frédéric
hal.structure.identifierLaboratoire national de métrologie et d'essais - Systèmes de Référence Temps-Espace [LNE - SYRTE]
dc.contributor.authorABGRALL, Michel
hal.structure.identifierMMTF
dc.contributor.authorCHARDONNET, Christian
hal.structure.identifierlp2n-06,lp2n-14
hal.structure.identifierLaboratoire national de métrologie et d'essais - Systèmes de Référence Temps-Espace [LNE - SYRTE]
dc.contributor.authorSANTARELLI, Giorgio
hal.structure.identifierLaboratoire de Physique des Lasers [LPL]
dc.contributor.authorDARQUIÉ, Benoît
hal.structure.identifierLaboratoire national de métrologie et d'essais - Systèmes de Référence Temps-Espace [LNE - SYRTE]
dc.contributor.authorLE COQ, Yann
hal.structure.identifierLaboratoire de Physique des Lasers [LPL]
dc.contributor.authorAMY-KLEIN, Anne
dc.date.accessioned2023-05-12T10:23:42Z
dc.date.available2023-05-12T10:23:42Z
dc.date.created2013
dc.date.issued2013
dc.identifier.issn1367-2630
dc.identifier.urihttps://oskar-bordeaux.fr/handle/20.500.12278/181182
dc.description.abstractEnWe present a new method for accurate mid-infrared frequency measurements and stabilization to a near-infrared ultra-stable frequency reference, transmitted with a long-distance fibre link and continuously monitored against state-of-the-art atomic fountain clocks. As a first application, we measure the frequency of an OsO4 rovibrational molecular line around 10 µm with a state-of-the-art uncertainty of 8x10-13. We also demonstrate the frequency stabilization of a mid-infrared laser with fractional stability better than 4x10-14 at 1 s averaging time and a line-width below 17 Hz. This new stabilization scheme gives us the ability to transfer frequency stability in the range of 10-15 or even better, currently accessible in the near-infrared or in the visible, to mid-infrared lasers in a wide frequency range.
dc.language.isoen
dc.publisherInstitute of Physics: Open Access Journals
dc.title.enMid-infrared laser phase-locking to a remote near-infrared frequency reference for high precision molecular spectroscopy
dc.typeArticle de revue
dc.identifier.doi10.1088/1367-2630/15/7/073003
dc.subject.halPhysique [physics]/Physique Quantique [quant-ph]
dc.subject.halPhysique [physics]/Physique [physics]/Optique [physics.optics]
dc.subject.halPhysique [physics]/Astrophysique [astro-ph]
dc.identifier.arxiv1304.7568
bordeaux.journalNew Journal of Physics
bordeaux.page073003
bordeaux.volume15
bordeaux.hal.laboratoriesLaboratoire Photonique, Numérique et Nanosciences (LP2N) - UMR 5298*
bordeaux.issue7
bordeaux.institutionUniversité de Bordeaux
bordeaux.institutionCNRS
bordeaux.peerReviewedoui
hal.identifierhal-00818440
hal.version1
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-00818440v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=New%20Journal%20of%20Physics&rft.date=2013&rft.volume=15&rft.issue=7&rft.spage=073003&rft.epage=073003&rft.eissn=1367-2630&rft.issn=1367-2630&rft.au=CHANTEAU,%20Bruno&LOPEZ,%20Olivier&ZHANG,%20Wei&NICOLODI,%20Daniele&ARGENCE,%20B%C3%A9reng%C3%A8re&rft.genre=article


Archivos en el ítem

ArchivosTamañoFormatoVer

No hay archivos asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem