Afficher la notice abrégée

hal.structure.identifierCentre de physique moléculaire optique et hertzienne [CPMOH]
dc.contributor.authorTRAVAILLÉ, Grégoire
hal.structure.identifierCentre d'Etudes Lasers Intenses et Applications [CELIA]
dc.contributor.authorPEYRUSSE, O.
hal.structure.identifierCentre de physique moléculaire optique et hertzienne [CPMOH]
dc.contributor.authorBOUSQUET, Bruno
hal.structure.identifierCentre de physique moléculaire optique et hertzienne [CPMOH]
dc.contributor.authorCANIONI, Lionel
hal.structure.identifierBureau de Recherches Géologiques et Minières [BRGM]
dc.contributor.authorMICHEL, Karine
hal.structure.identifierBureau de Recherches Géologiques et Minières [BRGM]
dc.contributor.authorROY, Stephane
dc.date.issued2009
dc.identifier.issn0584-8547
dc.description.abstractEnWe present a collisional-radiative approach of the theoretical analysis of laser-induced breakdown spectroscopy (LIBS) plasmas. This model, which relies on an optimized effective potential atomic structure code, was used to simulate a pure aluminum plasma. The description of aluminum involved a set of 220 atomic levels representative of three different stages of ionization (Al0, Al+ and Al++). The calculations were carried for stationary plasmas, with input parameters (ne and Te) ranging respectively between 1013-18 cm− 3 and 0.3-2 eV. A comparison of our atomic data with some existing databases is made. The code was mainly developed to address the validity of the local thermodynamic equilibrium (LTE) assumption. For usual LIBS plasma parameters, we did not reveal a sizeable discrepancy of the radiative equilibrium of the plasma towards LTE. For cases where LTE was firmly believed to stand, the Boltzmann plot outputs of this code were used to check the physical accuracy of the Boltzmann temperature, as it is currently exploited in several calibration-free laser-induced breakdown spectroscopy (CF-LIBS) studies. In this paper, a deviation ranging between 10 and 30% of the measured Boltzmann temperature to the real excitation temperature is reported. This may be due to the huge dispersion induced on the line emissivities, on which the Boltzmann plots are based to extract this parameter. Consequences of this fact on the CF-LIBS procedure are discussed and further insights to be considered for the future are introduced.
dc.language.isoen
dc.publisherElsevier
dc.subject.enLTE
dc.subject.enLaser-induced plasma
dc.subject.enCollisional-radiative model
dc.subject.enLIBS
dc.subject.enCF-LIBS
dc.title.enLocal thermodynamic equilibrium and related metrological issues involving collisional-radiative model in laser-induced aluminum plasmas
dc.typeArticle de revue
dc.identifier.doi10.1016/j.sab.2009.07.028
dc.subject.halChimie/Chimie analytique
bordeaux.journalSpectrochimica Acta Part B: Atomic Spectroscopy
bordeaux.pagep. 931-937
bordeaux.volume64
bordeaux.issue10
bordeaux.peerReviewedoui
hal.identifierhal-00516425
hal.version1
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-00516425v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Spectrochimica%20Acta%20Part%20B:%20Atomic%20Spectroscopy&rft.date=2009&rft.volume=64&rft.issue=10&rft.spage=p.%20931-937&rft.epage=p.%20931-937&rft.eissn=0584-8547&rft.issn=0584-8547&rft.au=TRAVAILL%C3%89,%20Gr%C3%A9goire&PEYRUSSE,%20O.&BOUSQUET,%20Bruno&CANIONI,%20Lionel&MICHEL,%20Karine&rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée