Afficher la notice abrégée

hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorMICHELET, Claire
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorBARBERET, Philippe
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorDEVÈS, Guillaume
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorBOUGUELMOUNA, B.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorBOURRET, S.
hal.structure.identifierInstitut de Chimie de la Matière Condensée de Bordeaux [ICMCB]
dc.contributor.authorDELVILLE, Marie-Hélène
hal.structure.identifierInstitut de Chimie de la Matière Condensée de Bordeaux [ICMCB]
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorLE TREQUESSER, Quentin
dc.contributor.authorGORDILLO, N.
hal.structure.identifierCentro de Ciências e Tecnologias Nucleares
hal.structure.identifierCentre for Medical Image Computing [CMIC]
dc.contributor.authorBEASLEY, D. G.
hal.structure.identifierCentro de Ciências e Tecnologias Nucleares
dc.contributor.authorMARQUES, A. C.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorFARAU, R.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorTOKO, B.
hal.structure.identifierGuelph-Waterloo Physics Institute
dc.contributor.authorCAMPBELL, J.
hal.structure.identifierGuelph-Waterloo Physics Institute
dc.contributor.authorMAXWELL, J.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorMORETTO, Philippe
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorSEZNEC, Hervé
dc.date.issued2015
dc.identifier.issn0168-583X
dc.description.abstractEnWe present here a new development of the TomoRebuild software package, to perform quantitative Particle Induced X-ray Emission Tomography (PIXET) reconstruction. X-ray yields are obtained from the GUPIX code. The GUPIX data base is available for protons up to 5 MeV and also in the 20–100 MeV energy range, deuterons up to 6 MeV, 3He and alphas up to 12 MeV. In this version, X-ray yields are calculated for thin samples, i.e. without simulating X-ray attenuation. PIXET data reconstruction is kept as long as possible independent from Scanning Transmission Ion Microscopy Tomography (STIMT). In this way, the local mass distribution (in g/cm3) of each X-ray emitting element is reconstructed in all voxels of the analyzed volume, only from PIXET data, without the need of associated STIMT data. Only the very last step of data analysis requires STIMT data, in order to normalize PIXET data to obtain concentration distributions, in terms of normalized mass fractions (in μg/g). For this, a noise correction procedure has been designed in ImageJ. Moreover sinogram or image misalignment can be corrected, as well as the difference in beam size between the two experiments. The main features of the TomoRebuild code, user friendly design and modular C++ implementation, were kept. The software package is portable and can run on Windows and Linux operating systems. An optional user-friendly graphic interface was designed in Java, as a plugin for the ImageJ graphic software package. Reconstruction examples are presented from biological specimens of Caenorhabditis elegans – a small nematode constituting a reference model for biology studies. The reconstruction results are compared between the different codes TomoRebuild, DISRA and JPIXET, and different reconstruction methods: Filtered BackProjection (FBP) and Maximum Likelihood Expectation Maximization (MLEM).
dc.description.sponsorshipMécanismes d'internalisation et de toxicité des nanoparticules d'oxyde de titane dans des organismes multicellulaires eucaryotes - ANR-10-CESA-0009
dc.language.isoen
dc.publisherElsevier
dc.subject.enPIXE tomography
dc.subject.enMLEM
dc.subject.enFiltered backprojection
dc.subject.enImageJ
dc.subject.enCaenorhabditis elegans
dc.title.enQuantitative reconstruction of PIXE-tomography data for thin samples using GUPIX X-ray emission yields
dc.typeArticle de revue
dc.identifier.doi10.1016/j.nimb.2014.11.035
dc.subject.halChimie/Matériaux
dc.description.sponsorshipEuropeSupport of Public and Industrial Research using Ion Beam Technology
bordeaux.journalNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
bordeaux.page92-99
bordeaux.volume348
bordeaux.peerReviewedoui
hal.identifierhal-01144075
hal.version1
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-01144075v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Nuclear%20Instruments%20and%20Methods%20in%20Physics%20Research%20Section%20B:%20Beam%20Interactions%20with%20Materials%20and%20Atoms&rft.date=2015&rft.volume=348&rft.spage=92-99&rft.epage=92-99&rft.eissn=0168-583X&rft.issn=0168-583X&rft.au=MICHELET,%20Claire&BARBERET,%20Philippe&DEV%C3%88S,%20Guillaume&BOUGUELMOUNA,%20B.&BOURRET,%20S.&rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée