Afficher la notice abrégée

hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorFONTBONNE, C.
dc.contributor.authorUJIĆ, P.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorDE OLIVEIRA SANTOS, F.
hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorFLÉCHARD, X.
dc.contributor.authorROTARU, F.
hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorACHOURI, N.L.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorGIRARD ALCINDOR, V.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorBASTIN, B.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorBOULAY, F.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorBRIAND, J.B.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorSÁNCHEZ-BENÍTEZ, A.M.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorBOUZOMITA, H.
dc.contributor.authorBORCEA, C.
dc.contributor.authorBORCEA, R.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorBLANK, B.
hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorCARNIOL, B.
dc.contributor.authorČELIKOVIĆ, I.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorDELAHAYE, P.
hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorDELAUNAY, F.
hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorETASSE, D.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorFREMONT, G.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorDE FRANCE, G.
hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorFONTBONNE, J.M.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorGRINYER, G.F.
hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorHARANG, J.
hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorHOMMET, J.
dc.contributor.authorJEVREMOVIĆ, A.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorLEWITOWICZ, M.
dc.contributor.authorMARTEL, I.
dc.contributor.authorMRAZEK, J.
hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorPARLOG, M.
hal.structure.identifierLaboratoire de physique corpusculaire de Caen [LPCC]
dc.contributor.authorPOINCHEVAL, J.
dc.contributor.authorRAMOS, D.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorSPITAELS, C.
dc.contributor.authorSTANOIU, M.
hal.structure.identifierGrand Accélérateur National d'Ions Lourds [GANIL]
dc.contributor.authorTHOMAS, J.C.
dc.contributor.authorTOPREK, D.
dc.date.issued2017
dc.description.abstractEnThe half-life of Ne19 was measured using a real-time digital multiparametric acquisition system, providing an accurate time stamp and relevant information on the detector signals for each decay event. An exhaustive offline analysis of the data gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement such as after-pulses, pile-up, gain, and baseline fluctuations, their effects were accurately estimated and the event selection optimized. The resulting half-life, 17.2569±0.0019(stat)±0.0009(syst) s, is the most precise up to now for Ne19. It is found to be in agreement with two recent precise measurements and not consistent with the most recent one [L. J. Broussard , Phys. Rev. Lett. 112, 212301 (2014)PRLTAO0031-900710.1103/PhysRevLett.112.212301] by 3.0 standard deviations. The full potential of the technique for nuclei with half-lives of a few seconds is discussed.
dc.language.isoen
dc.subject.en24.80.+y
dc.subject.en23.40.-s
dc.subject.en12.15.Hh
dc.subject.en12.60.-i
dc.title.enHigh precision measurement of the $^{19}$Ne $\beta$-decay half-life using real-time digital acquisition
dc.typeArticle de revue
dc.identifier.doi10.1103/PhysRevC.96.065501
dc.subject.halPhysique [physics]/Physique Nucléaire Expérimentale [nucl-ex]
dc.subject.halPhysique [physics]/Physique [physics]/Instrumentations et Détecteurs [physics.ins-det]
dc.identifier.arxiv1709.09415
bordeaux.journalPhys.Rev.C
bordeaux.page065501
bordeaux.volume96
bordeaux.issue6
bordeaux.peerReviewedoui
hal.identifierhal-01669781
hal.version1
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-01669781v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Phys.Rev.C&rft.date=2017&rft.volume=96&rft.issue=6&rft.spage=065501&rft.epage=065501&rft.au=FONTBONNE,%20C.&UJI%C4%86,%20P.&DE%20OLIVEIRA%20SANTOS,%20F.&FL%C3%89CHARD,%20X.&ROTARU,%20F.&rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée