Afficher la notice abrégée

hal.structure.identifierCentre d'Etudes Lasers Intenses et Applications [CELIA]
dc.contributor.authorRABHI, N.
hal.structure.identifierCentre d'Etudes Lasers Intenses et Applications [CELIA]
dc.contributor.authorBATANI, D.
hal.structure.identifierCentre d'Etudes Lasers Intenses et Applications [CELIA]
dc.contributor.authorBOUTOUX, G.
hal.structure.identifierCentre d'Etudes Lasers Intenses et Applications [CELIA]
dc.contributor.authorDUCRET, J.-E.
hal.structure.identifierCentre d'Etudes Lasers Intenses et Applications [CELIA]
dc.contributor.authorJAKUBOWSKA, K.
hal.structure.identifierDirection des Applications Militaires [DAM]
dc.contributor.authorLANTUEJOUL-THFOIN, I.
hal.structure.identifierInstitut Curie [Paris]
dc.contributor.authorNAURAYE, C.
hal.structure.identifierInstitut Curie [Paris]
dc.contributor.authorPATRIARCA, A.
hal.structure.identifierInstitut de Physique Nucléaire d'Orsay [IPNO]
dc.contributor.authorSAÏD, A.
hal.structure.identifierInstitut de Physique Nucléaire d'Orsay [IPNO]
dc.contributor.authorSEMSOUM, A.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorSERANI, L.
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorTHOMAS, B.
hal.structure.identifierDirection des Applications Militaires [DAM]
dc.contributor.authorVAUZOUR, B.
dc.date.issued2017
dc.description.abstractEnResponses of Fuji Imaging Plates (IPs) to proton have been measured in the range 1-200 MeV. Mono-energetic protons were produced with the 15 MV ALTO-Tandem accelerator of the Institute of Nuclear Physics (Orsay, France) and, at higher energies, with the 200-MeV isochronous cyclotron of the Institut Curie—Centre de Protonthérapie d’Orsay (Orsay, France). The experimental setups are described and the measured photo-stimulated luminescence responses for MS, SR, and TR IPs are presented and compared to existing data. For the interpretation of the results, a sensitivity model based on the Monte Carlo GEANT4 code has been developed. It enables the calculation of the response functions in a large energy range, from 0.1 to 200 MeV. Finally, we show that our model reproduces accurately the response of more complex detectors, i.e., stack of high-Z filters and IPs, which could be of great interest for diagnostics of Petawatt laser accelerated particles
dc.language.isoen
dc.title.enCalibration of imaging plate detectors to mono-energetic protons in the range 1-200 MeV
dc.typeArticle de revue
dc.identifier.doi10.1063/1.5009472
dc.subject.halPhysique [physics]/Physique [physics]/Instrumentations et Détecteurs [physics.ins-det]
bordeaux.journalRev.Sci.Instrum.
bordeaux.page113301
bordeaux.volume88
bordeaux.issue11
bordeaux.peerReviewedoui
hal.identifierhal-01851242
hal.version1
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-01851242v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Rev.Sci.Instrum.&rft.date=2017&rft.volume=88&rft.issue=11&rft.spage=113301&rft.epage=113301&rft.au=RABHI,%20N.&BATANI,%20D.&BOUTOUX,%20G.&DUCRET,%20J.-E.&JAKUBOWSKA,%20K.&rft.genre=article


Fichier(s) constituant ce document

FichiersTailleFormatVue

Il n'y a pas de fichiers associés à ce document.

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée