Mostrar el registro sencillo del ítem

hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorMICHELET, Claire
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorLI, Zhuxin
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorYANG, Wen
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorINCERTI, Sébastien
hal.structure.identifierLaboratoire Bordelais de Recherche en Informatique [LaBRI]
dc.contributor.authorDESBARATS, Pascal
hal.structure.identifierLaboratoire de l'intégration, du matériau au système [IMS]
dc.contributor.authorGIOVANNELLI, Jean-François
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorBARBERET, Philippe
hal.structure.identifierInstitut de Chimie de la Matière Condensée de Bordeaux [ICMCB]
dc.contributor.authorDELVILLE, Marie-Hélène
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorGORDILLO, Nuria
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorDEVÈS, Guillaume
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorSEZNEC, Hervé
dc.date.issued2019-09
dc.identifier.issn1120-1797
dc.description.abstractEnProton imaging can be carried out on microscopic samples by focusing the beam to a diameter ranging from a few micrometers down to a few tens of nanometers, depending on the required beam intensity and spatial resolution. Three-dimensional (3D) imaging by tomography is obtained from proton transmission (STIM: Scanning Transmission Ion Microscopy) and/or X-ray emission (PIXE: Particle Induced X-ray Emission). In these experiments, the samples are dehydrated for under vacuum analysis. In situ quantification of nanoparticles has been carried out at CENBG in the frame of nanotoxicology studies, on cells and small organisms used as biological models, especially on Caenorhabditis elegans (C. elegans) nematodes. Tomography experiments reveal the distribution of mass density and chemical content (in g.cm−3) within the analyzed volume. These density values are obtained using an inversion algorithm. To investigate the effect of this data reduction process, we defined different numerical phantoms, including a (dehydrated) C. elegans phantom whose geometry and density were derived from experimental data. A Monte Carlo simulation based on the Geant4 toolkit was developed. Using different simulation and reconstruction conditions, we compared the resulting tomographic images to the initial numerical reference phantom. A study of the relative error between the reconstructed and the reference images lead to the result that 20 protons per shot can be considered as an optimal number for 3D STIM imaging. Preliminary results for PIXE tomography are also presented, showing the interest of such numerical phantoms to produce reference data for future studies on X-ray signal attenuation in thick samples.
dc.language.isoen
dc.publisherElsevier
dc.subject.enGeant4 simulation
dc.subject.enSTIM tomography
dc.subject.enPIXE tomography
dc.subject.enCaenorhabditis elegans
dc.subject.meshAnimals
dc.subject.meshCaenorhabditis elegans
dc.subject.meshImage Processing, Computer-Assisted
dc.subject.meshImaging, Three-Dimensional
dc.subject.meshMicroscopy
dc.subject.meshMonte Carlo Method
dc.subject.meshPhantoms, Imaging
dc.subject.meshProtons
dc.title.enA Geant4 simulation for three-dimensional proton imaging of microscopic samples
dc.typeArticle de revue
dc.identifier.doi10.1016/j.ejmp.2019.08.022
dc.subject.halChimie/Matériaux
bordeaux.journalPhysica Medica
bordeaux.page172-180
bordeaux.volume65
bordeaux.peerReviewedoui
hal.identifierhal-02281684
hal.version1
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-02281684v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Physica%20Medica&rft.date=2019-09&rft.volume=65&rft.spage=172-180&rft.epage=172-180&rft.eissn=1120-1797&rft.issn=1120-1797&rft.au=MICHELET,%20Claire&LI,%20Zhuxin&YANG,%20Wen&INCERTI,%20S%C3%A9bastien&DESBARATS,%20Pascal&rft.genre=article


Archivos en el ítem

ArchivosTamañoFormatoVer

No hay archivos asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem