Mostrar el registro sencillo del ítem

hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorLI, Zhuxin
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorMICHELET, Claire
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorINCERTI, Sebastien
hal.structure.identifierEuropean Organization for Nuclear Research [CERN]
hal.structure.identifierTomsk State University [Tomsk]
dc.contributor.authorIVANCHENKO, Vladimir
hal.structure.identifierEuropean Organization for Nuclear Research [CERN]
dc.contributor.authorNOVAK, Mihaly
hal.structure.identifierUniversity of Wollongong [Australia]
dc.contributor.authorGUATELLI, Susanna
hal.structure.identifierCentre d'Etudes Nucléaires de Bordeaux Gradignan [CENBG]
dc.contributor.authorSEZNEC, Hervé
dc.date.issued2022-03
dc.identifier.issn1120-1797
dc.description.abstractEnThis paper describes in detail the implementation of Geant4 Livermore electromagnetic physics models based on the EPICS2017 database for the low energy transport of photons. These models describe four photon processes: gamma conversion, Compton scattering, photoelectric effect and Rayleigh scattering. New parameterizations based on EPICS2017 were performed for scattering functions of Compton effect, subshell cross-sections of the photoelectric effect and form factors of Rayleigh scattering, in order to improve the precision of fitted values compared to tabulated values. Comparisons between new and old parameterizations were also carried out to evaluate the precision of the new parameterizations. The models were tested through a comparative study, in which the mass attenuation coefficient was calculated for both total photon interaction and each process using Geant4 simulations based on EPICS2017 and EPDL97 respectively. The results obtained from the simulations were found in good agreement with the XCOM reference data.
dc.language.isoen
dc.publisherElsevier
dc.subject.enGeant4
dc.subject.enEPICS2017
dc.subject.enLivermore
dc.subject.enXCOM
dc.subject.enMass attenuation coefficient
dc.title.enImplementation of the EPICS2017 database for photons in Geant4
dc.typeArticle de revue
dc.identifier.doi10.1016/j.ejmp.2022.01.008
dc.subject.halPhysique [physics]
bordeaux.journalPhysica Medica
bordeaux.page94-115
bordeaux.volume95
bordeaux.peerReviewedoui
hal.identifierhal-03582830
hal.version1
hal.popularnon
hal.audienceInternationale
hal.origin.linkhttps://hal.archives-ouvertes.fr//hal-03582830v1
bordeaux.COinSctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.jtitle=Physica%20Medica&rft.date=2022-03&rft.volume=95&rft.spage=94-115&rft.epage=94-115&rft.eissn=1120-1797&rft.issn=1120-1797&rft.au=LI,%20Zhuxin&MICHELET,%20Claire&INCERTI,%20Sebastien&IVANCHENKO,%20Vladimir&NOVAK,%20Mihaly&rft.genre=article


Archivos en el ítem

ArchivosTamañoFormatoVer

No hay archivos asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem